Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"17beta-Estradiol increases, aging decreases, c-Fos expression in the rat accessory olfactory bulb"    Next AbstractCharacterization and fingerprinting of soil and groundwater contamination sources around a fuel distribution station in Galicia (NW Spain) »

J Air Waste Manag Assoc


Title:Evaluation of an Automatic Composite Sampler for Volatile Organic Compounds in Raw Wastewater
Author(s):Balogh S; Onayiga R; Edblad D;
Address:"a Metropolitan Council Environmental Services , St. Paul , Minnesota , USA"
Journal Title:J Air Waste Manag Assoc
Year:1998
Volume:48
Issue:3
Page Number:271 - 275
DOI: 10.1080/10473289.1998.10463675
ISSN/ISBN:2162-2906 (Electronic) 1096-2247 (Linking)
Abstract:"The measurement of volatile organic compound (VOC) emission rates from wastewater treatment processes is difficult and costly, so estimation techniques are frequently employed. To use these techniques, VOC concentrations in the raw wastewater entering the plant typically must be known. However, representative data on time-varying influent VOC concentrations are typically not available, and the collection of sufficient data to make a reliable loading estimate can be quite expensive. A composite VOC sampler can reduce the cost of obtaining these data; however, such samplers are not in widespread use and questions remain regarding their suitability for use on raw wastewater streams. In this study, an automatic composite VOC sampler was used to measure VOC concentrations in raw wastewa-ter, and the results were compared to VOC concentrations in grab samples obtained over the same period. The results suggest that the composite VOC sampler can provide a reasonably accurate estimate of VOC concentrations in raw wastewater streams. The composite sampler required modification to prevent plugging by solids in the high-solids wastewater stream"
Keywords:
Notes:"PubMed-not-MEDLINEBalogh, Steven Onayiga, Richard Edblad, Debra eng 1998/03/01 J Air Waste Manag Assoc. 1998 Mar; 48(3):271-275. doi: 10.1080/10473289.1998.10463675"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 03-07-2024