Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractExpression and function of sex pheromones and receptors in the homothallic ascomycete Gibberella zeae    Next AbstractMethods for evaluating the Caenorhabditis elegans dauer state: standard dauer-formation assay using synthetic daumones and proteomic analysis of O-GlcNAc modifications »

J Appl Physiol (1985)


Title:Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds
Author(s):Lee J; Ngo J; Blake D; Meinardi S; Pontello AM; Newcomb R; Galassetti PR;
Address:"Department of Pharmacology, University of California, Irvine, Orange, California 92868, USA"
Journal Title:J Appl Physiol (1985)
Year:2009
Volume:20090507
Issue:1
Page Number:155 - 160
DOI: 10.1152/japplphysiol.91657.2008
ISSN/ISBN:8750-7587 (Print) 1522-1601 (Electronic) 0161-7567 (Linking)
Abstract:"Exhaled volatile organic compounds (VOCs) represent ideal biomarkers of endogenous metabolism and could be used to noninvasively measure circulating variables, including plasma glucose. We previously demonstrated that hyperglycemia in different metabolic settings (glucose ingestion in pediatric Type 1 diabetes) is paralleled by changes in exhaled ethanol, acetone, and methyl nitrate. In this study we integrated these gas changes along with three additional VOCs (2 forms of xylene and ethylbenzene) into multi-linear regression models to predict plasma glucose profiles in 10 healthy young adults, during the 2 h following an intravenous glucose bolus (matched samples of blood, exhaled and room air were collected at 12 separate time points). The four-gas model with highest predictive accuracy estimated plasma glucose in each subject with a mean R value of 0.91 (range 0.70-0.98); increasing the number of VOCs in the model only marginally improved predictions (average R with best 5-gas model = 0.93; with 6-gas model = 0.95). While practical development of this methodology into clinically usable devices will require optimization of predictive algorithms on large-scale populations, our data prove the feasibility and potential accuracy of breath-based glucose testing"
Keywords:"Acetone/analysis Adult Blood Glucose/*analysis Breath Tests/*methods Diabetes Mellitus/blood/diagnosis Ethanol/analysis Exhalation Female Glucose Humans Injections, Intravenous *Linear Models Male Nitrates/analysis Predictive Value of Tests Volatile Organ;"
Notes:"MedlineLee, Jane Ngo, Jerry Blake, Don Meinardi, Simone Pontello, Andria M Newcomb, Robert Galassetti, Pietro R eng M01 RR000827/RR/NCRR NIH HHS/ MO1- RR00827-28/RR/NCRR NIH HHS/ Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't 2009/05/09 J Appl Physiol (1985). 2009 Jul; 107(1):155-60. doi: 10.1152/japplphysiol.91657.2008. Epub 2009 May 7"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 24-09-2024