Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDental calculus composition following use of essential-oil/ZnCl2 mouthrinse    Next AbstractComparison of the Sex Pheromone Composition of Harmonia axyridis Originating from Native and Invaded Areas »

Anal Chem


Title:Determining chemical activity of (semi)volatile compounds by headspace solid-phase microextraction
Author(s):Legind CN; Karlson U; Burken JG; Reichenberg F; Mayer P;
Address:"Department of Environmental Chemistry and Microbiology, National Environmental Research Institute, University of Aarhus, Frederiksborgvej 399, 4000 Roskilde, Denmark. chni@dmu.dk"
Journal Title:Anal Chem
Year:2007
Volume:20070222
Issue:7
Page Number:2869 - 2876
DOI: 10.1021/ac061880o
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"This research introduces a new analytical methodology for measuring chemical activity of nonpolar (semi)volatile organic compounds in different sample matrices using automated solid-phase microextraction (SPME). The chemical activity of an analyte is known to determine its equilibrium concentration in the SPME fiber coating. On this basis, SPME was utilized for the analytical determination of chemical activity, fugacity, and freely dissolved concentration using these steps: (1) a sample is brought into a vial, (2) the SPME fiber is introduced into the headspace and equilibrated with the sample, (3) the SPME fiber is injected into the GC for thermal desorption and analysis, and (4) the method is calibrated by SPME above partitioning standards in methanol. Model substances were BTEX, naphthalene, and alkanes, which were measured in a variety of sample types: liquid polydimethylsiloxane (PDMS), wood, soil, and nonaqueous phase liquid (NAPL). Variable sample types (i.e., matrices) had no influence on sampling kinetics because diffusion through the headspace was rate limiting for the overall sampling process. Sampling time was 30 min, and relative standard deviations were generally below 5% for homogeneous solutions and somewhat higher for soil and NAPL. This type of activity measurement is fast, reliable, almost solvent free, and applicable for mixed-media sampling"
Keywords:
Notes:"PubMed-not-MEDLINELegind, Charlotte N Karlson, Ulrich Burken, Joel G Reichenberg, Fredrik Mayer, Philipp eng 2007/02/23 Anal Chem. 2007 Apr 1; 79(7):2869-76. doi: 10.1021/ac061880o. Epub 2007 Feb 22"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-11-2024