Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractRole of export industries on ozone pollution and its precursors in China    Next Abstract"Volatile molecular markers of VOO Thermo-oxidation: Effect of heating processes, macronutrients composition, and olive ripeness on the new emitted aldehydic compounds" »

Anal Chem


Title:"Real-time, on-line characterization of diesel generator air toxic emissions by resonance-enhanced multiphoton ionization time-of-flight mass spectrometry"
Author(s):Oudejans L; Touati A; Gullett BK;
Address:"Office of Research and Development, National Risk Management Research Laboratory, US Environmental Protection Agency, Research Triangle Park, North Carolina 27711, USA"
Journal Title:Anal Chem
Year:2004
Volume:76
Issue:9
Page Number:2517 - 2524
DOI: 10.1021/ac035390x
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"The laser-based resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (REMPI-TOFMS) technique has been applied to the exhaust gas stream of a diesel generator to measure, in real time, concentration levels of aromatic air toxics. Volatile organic compounds, as well as several polycyclic aromatic hydrocarbons were detected in the concentration range of 10-200 ppb in the steady-state diesel generator exhaust. The results were verified and compared with conventional extractive sampling and analytical techniques using gas chromatography/mass spectrometry (GC/MS). The high isomer selectivity of the REMPI-TOFMS instrument provided data for individual xylene isomers that are otherwise (partially) coeluting in standard GC/MS analyses. Good agreement was observed between results for volatile and semivolatile organic compounds obtained with REMPI-TOFMS and conventional extractive sampling. Transient events, such as cold start-ups of the diesel generator, resulted in sharp (less than 15 s) peak emissions that were, for benzene, up to a factor of 90 higher than the predominately constant concentrations observed during steady-state operation; warm restarts resulted in lower peak concentrations by a factor of 2.5. These fast transient emissions are only detectable using a real-time approach (1-s resolution) as demonstrated here using REMPI-TOFMS"
Keywords:
Notes:"PubMed-not-MEDLINEOudejans, Lukas Touati, Abderrahmane Gullett, Brian K eng 2004/05/01 Anal Chem. 2004 May 1; 76(9):2517-24. doi: 10.1021/ac035390x"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024