Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractHerbicide and Cytogenotoxic Activity of Inclusion Complexes of Psidium gaudichaudianum Leaf Essential Oil and beta-Caryophyllene on 2-Hydroxypropyl-beta-cyclodextrin    Next AbstractHeadspace membrane introduction mass spectrometry for trace level analysis of VOCs in soil and other solid matrixes »

Anal Chem


Title:A Cryotrap Membrane Introduction Mass Spectrometry System for Analysis of Volatile Organic Compounds in Water at the Low Parts-per-Trillion Level
Author(s):Mendes MA; Pimpim RS; Kotiaho T; Eberlin MN;
Address:"Institute of Chemistry, State University of Campinas [Formula: see text] UNICAMP, CP 6154, 13083-970 Campinas, SP, Brazil"
Journal Title:Anal Chem
Year:1996
Volume:68
Issue:19
Page Number:3502 - 3506
DOI: 10.1021/ac9604346
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"Detection of volatile organic compounds (VOCs) in aqueous solution at low parts-per-trillion (ppt) levels is accomplished using a very simple and efficient on-line preconcentration cryotrap membrane introduction mass spectrometry (CT-MIMS) system. The conventional MIMS probe is modified so that the membrane interface is placed about 15 cm away from the ion source. A U-shaped trap tube is then inserted between the membrane interface and the ion source. Cryotrapping is performed with liquid nitrogen for 15 min, followed by fast heating at approximately 15 degrees C s(-)(1), which thermally releases the condensed VOCs almost at once into the ion source region of a quadrupole mass spectrometer. By applying electron ionization and a selective ion monitoring scan mode, a very sharp and intense peak is obtained. The performance of the CT-MIMS system was compared with that of conventional MIMS, and after reaching the best conditions for the trapping and heating cycles, an improvement factor in signal intensity of about 100 was observed for a series of VOCs. The extraordinary sensitivity of CT-MIMS system allows VOCs to be detected at very low concentrations, detection limits being typically on the order of 10-20 ppt. The results also show excellent linearity and reproducibility for the system"
Keywords:
Notes:"PubMed-not-MEDLINEMendes, M A Pimpim, R S Kotiaho, T Eberlin, M N eng 1996/10/01 Anal Chem. 1996 Oct 1; 68(19):3502-6. doi: 10.1021/ac9604346"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024