Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEffectiveness of Purge-and-Trap for Measurement of Volatile Organic Compounds in Aged Soils    Next AbstractCharacterization of antimicrobial resistance and virulence genotypes of Enterococcus faecalis recovered from a pork processing plant »

Anal Chem


Title:Development of needle trap technology for on-site determinations: active and passive sampling
Author(s):Asl-Hariri S; Gomez-Rios GA; Gionfriddo E; Dawes P; Pawliszyn J;
Address:"Department of Chemistry, University of Waterloo , Waterloo, Ontario, Canada N2L 3G1"
Journal Title:Anal Chem
Year:2014
Volume:20140604
Issue:12
Page Number:5889 - 5897
DOI: 10.1021/ac500801v
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"This study presents a thorough evaluation of new prototypes of extended tip needle trap devices (NT), as well as their application to in situ sampling of biological emissions and active/passive on-site sampling of indoor air. A new NT prototype was constructed with a side hole above the sorbent and an extended tip that fits inside the restriction of the narrow neck liner to increase desorption efficiency. New prototype needles were initially packed with divinylbenzene particles at SGE Analytical Science for the purpose of studying biogenic emissions of pine trees. Prior to their final application, they were evaluated in terms of robustness after multiple use (n > 10), as well as amount extracted of volatile organic compounds (VOCs). An ANOVA test for all the probes showed that at a 95% level of confidence, there were not statistical differences observed among the 9 NTs tested. In addition, the needles were also packed in laboratory with synthesized highly cross-linked PDMS as a frit to immobilize carboxen (Car) particles for spot sampling. For passive sampling, the needles were packed with Car particles embedded in PDMS to simplify calculations in passive mode. The use of NTs as spot samplers, as well as a passive sampler under controlled conditions in the laboratoryyielded a relative standard deviation of less than 15%. Finally, a new, reusable and readily deployable penlike diffusive sampler for needle traps (PDS-NT) was built and tested. Application of the PDS-NT in combination with NT-spot sampling toward the analysis of indoor air in a polymer synthesis laboratory showed good agreement between both techniques for the analyte studied, yielding averages of 0.03 and 0.025 ng/mL of toluene, respectively"
Keywords:
Notes:"PubMed-not-MEDLINEAsl-Hariri, Saba Gomez-Rios, German A Gionfriddo, Emanuela Dawes, Peter Pawliszyn, Janusz eng 2014/05/21 Anal Chem. 2014 Jun 17; 86(12):5889-97. doi: 10.1021/ac500801v. Epub 2014 Jun 4"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024