Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVolatile compounds in health and disease    Next AbstractA quantitative study of the influence of inhaled compounds on their concentrations in exhaled breath »

Eur J Mass Spectrom (Chichester)


Title:"On the features, successes and challenges of selected ion flow tube mass spectrometry"
Author(s):Spanel P; Smith D;
Address:"J. Heyrovsky Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, DolejSkova 3, 182 23, Prague 8, Czech Republic. lnstitute for Science and Technology in Medicine, Keele University, Guy Hilton Research Centre, Thornburrow Drive, Hartshill, Stoke-on-Trent ST4 7QB, UK"
Journal Title:Eur J Mass Spectrom (Chichester)
Year:2013
Volume:19
Issue:4
Page Number:225 - 246
DOI: 10.1255/ejms.1240
ISSN/ISBN:1469-0667 (Print) 1469-0667 (Linking)
Abstract:"The major features of the selected ion flow tube mass spectrometry (SIFT-MS) analytical method that was conceived and designed for the analysis, in real time, of air obviating sample collections into bags or extraction by pre-concentration of trace compounds onto surfaces are reviewed. The unique analytical capabilities of SIFT-MS for ambient analysis are stressed that allow quantification of volatile organic and inorganic compounds directly from the measurement of physical parameters without the need for regular instrumental calibration using internal or external standards. Then, emphasis is placed on the challenging real-time accurate analysis of single exhalations of humid breath, which is now achieved and readily facilitates wider applications of SIFT-MS in other fields where trace gas analysis has value. The quality of the data obtained by SIFT-MS is illustrated by the quantification of some exhaled breath metabolites that are of immediate relevance to physiology and medicine, including that of hydrogen cyanide in the breath of patients with cystic fibrosis. The current status of SIFT-MS is revealed by a form of a strengths, weakness, opportunities and threats (SWOT) analysis intended to present an objective view of this analytical technique and the likely way forward towards its further development and application"
Keywords:
Notes:"PubMed-not-MEDLINESpanel, Patrik Smith, David eng England 2014/03/01 Eur J Mass Spectrom (Chichester). 2013; 19(4):225-46. doi: 10.1255/ejms.1240"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024