« Previous AbstractRequirement for Drosophila SNMP1 for rapid activation and termination of pheromone-induced activity    Next AbstractReal-time ultrasensitive VUV-PIMS detection of representative endogenous volatile markers in cancers »

Talanta


Title:A solid phase microextraction fiber coated with graphene-poly(ethylene glycol) composite for the extraction of volatile aromatic compounds from water samples
Author(s):Li Z; Ma R; Bai S; Wang C; Wang Z;
Address:"Department of Chemistry, College of Science, Agricultural University of Hebei, Baoding 071001, China; College of Food Science & Technology, Agricultural University of Hebei, Baoding 071001, China. Department of Chemistry, College of Science, Agricultural University of Hebei, Baoding 071001, China. College of Food Science & Technology, Agricultural University of Hebei, Baoding 071001, China. Department of Chemistry, College of Science, Agricultural University of Hebei, Baoding 071001, China; College of Food Science & Technology, Agricultural University of Hebei, Baoding 071001, China. Electronic address: zhiwang2000@hotmail.com"
Journal Title:Talanta
Year:2014
Volume:20131201
Issue:
Page Number:498 - 504
DOI: 10.1016/j.talanta.2013.11.068
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"Poly(ethylene glycol)-grafted graphene (PEG-g-G) was prepared and used as the solid phase microextraction (SPME) fiber coating for the extraction of seven volatile aromatic compounds (VACs) from water samples followed by the determination with gas chromatography-flame ionization detection. The PEG-g-G coating was characterized by both the thermal gravimetric analysis and scanning electron microscopy. The results verified that the PEG was successfully grafted onto the surface of graphene and the coating had a highly porous structure. Several important experimental parameters that could influence the SPME efficiency were investigated and optimized. Under the optimized conditions, the limits of detection were in the range from 1.0 to 6.0 ng L(-1). The relative standard deviations for intraday and interday variations were in the range of 1.8-5.8% and 5.1-8.3%, and for fiber-to-fiber variations, were between 6.5 and 11.9%, respectively. The results indicated that the PEG-g-G fiber had the advantages of high extraction efficiency and good thermal stability and durability. It can be reused more than 200 times without a significant loss of extraction efficiency. The method was successfully applied to the analysis of seven VACs in tap, river and mineral water samples"
Keywords:"Chromatography, Gas Graphite/*chemistry Microscopy, Electron, Scanning Polyethylene Glycols/*chemistry Reproducibility of Results Solid Phase Microextraction/*instrumentation Volatile Organic Compounds/*isolation & purification Water Pollutants, Chemical/;"
Notes:"MedlineLi, Zhi Ma, Ruiyang Bai, Shasha Wang, Chun Wang, Zhi eng Research Support, Non-U.S. Gov't Validation Study Netherlands 2014/01/10 Talanta. 2014 Feb; 119:498-504. doi: 10.1016/j.talanta.2013.11.068. Epub 2013 Dec 1"

 