Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEmergence and fate of volatile iodinated organic compounds during biological treatment of oil and gas produced water    Next Abstract"Development of a plasma-assisted cataluminescence system for benzene, toluene, ethylbenzene, and xylenes analysis" »

Rapid Commun Mass Spectrom


Title:Development of a graphite low-temperature plasma source with dual-mode in-source fragmentation for ambient mass spectrometry
Author(s):Almasian MR; Yang C; Xing Z; Zhang S; Zhang X;
Address:"Department of Chemistry, Key Laboratory for Atomic and Molecular Nanosciences of Education Ministry, Tsinghua University, 100084 Beijing, PR China"
Journal Title:Rapid Commun Mass Spectrom
Year:2010
Volume:24
Issue:6
Page Number:742 - 748
DOI: 10.1002/rcm.4444
ISSN/ISBN:1097-0231 (Electronic) 0951-4198 (Linking)
Abstract:"A new low-temperature plasma (LTP), based on dielectric barrier discharge (DBD), has been developed as an alternative ionization source for ambient mass spectrometry. For organic samples, the source is able to produce two different fragmentation patterns which are selectable by an electrical switch. The two source modes are different only in the second electrodes: in configuration (A), bar-plate and in configuration (B), coaxial bar-cylinder shapes are used. A disposable graphite probe is used as the first electrode, the same in both configurations, and a copper foil is used as the second electrode. The ionization source is applicable to gas and liquid samples, without any change being necessary in its design. Under optimal conditions, to take ethylbenzene as an example, a detection limit of less than 25 ng was obtained and a relative standard deviation (RSD) of 13.36% has been demonstrated for 50 ng of ethylbenzene (n = 11). We have found several interesting differences in the mass spectra of the tested volatile organic compounds (VOCs) in the two modes, which might be applicable in identification studies. We have investigated the effect of variation of the first electrode material and the second electrode length in mode B. Moreover, in this design the graphite electrode is capable of acting as a sample adsorbent, which is a new sampling method for LTP mass spectrometry (MS). This capability was investigated by adsorption of the selected VOCs onto the surface of the graphite electrode in a headspace solid-phase microextraction (SPME) system, and direct desorption and ionization of the samples by LTPMS"
Keywords:
Notes:"PubMed-not-MEDLINEAlmasian, Mohammad Reza Yang, Chengdui Xing, Zhi Zhang, Sichun Zhang, Xinrong eng England 2010/02/20 Rapid Commun Mass Spectrom. 2010 Mar; 24(6):742-8. doi: 10.1002/rcm.4444"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 30-12-2024