Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractThe Transcription Factor OsWRKY45 Negatively Modulates the Resistance of Rice to the Brown Planthopper Nilaparvata lugens    Next AbstractPheromone and other chemical communication »

Environ Sci Technol


Title:Whole-House Emission Rates and Loss Coefficients of Formaldehyde and Other Volatile Organic Compounds as a Function of the Air Change Rate
Author(s):Huangfu Y; Lima NM; O'Keeffe PT; Kirk WM; Lamb BK; Walden VP; Jobson BT;
Address:"Laboratory for Atmospheric Research, Department of Civil and Environmental Engineering , Washington State University , Pullman 99164 , Washington , United States. School of Architecture and Construction Management , Washington State University , Pullman 99164 , Washington , United States"
Journal Title:Environ Sci Technol
Year:2020
Volume:20200128
Issue:4
Page Number:2143 - 2151
DOI: 10.1021/acs.est.9b05594
ISSN/ISBN:1520-5851 (Electronic) 0013-936X (Linking)
Abstract:"Whole-house emission rates and indoor loss coefficients of formaldehyde and other volatile organic compounds (VOCs) were determined from continuous measurements inside a net-zero energy home at two different air change rates (ACHs). By turning the mechanical ventilation on and off, it was demonstrated that formaldehyde concentrations reach a steady state much more quickly than other VOCs, consistent with a significant indoor loss rate attributed to surface uptake. The first order loss coefficient for formaldehyde was 0.47 +/- 0.06 h(-1) at 0.08 h(-1) ACH and 0.88 +/- 0.22 h(-1) at 0.62 h(-1) ACH. Loss rates for other VOCs measured were not discernible, with the exception of hexanoic acid. A factor of 5.5 increase in the ACH increased the whole-house emission rates of VOCs but by varying degrees (factors of 1.1 to 3.8), with formaldehyde displaying no significant change. The formaldehyde area-specific emission rate (86 +/- 8 mug m(-2) h(-1)) was insensitive to changes in the ACH because its large indoor loss rate muted the impact of ventilation on indoor air concentrations. These results demonstrate that formaldehyde loss rates must be taken into account to correctly estimate whole-house emission rates and that ventilation will not be as effective at reducing indoor formaldehyde concentrations as it is for other VOCs"
Keywords:"*Air Pollutants *Air Pollution, Indoor Environmental Monitoring Formaldehyde Ventilation *Volatile Organic Compounds;"
Notes:"MedlineHuangfu, Yibo Lima, Nathan M O'Keeffe, Patrick T Kirk, William M Lamb, Brian K Walden, Von P Jobson, Bertram T eng Research Support, U.S. Gov't, Non-P.H.S. 2020/01/04 Environ Sci Technol. 2020 Feb 18; 54(4):2143-2151. doi: 10.1021/acs.est.9b05594. Epub 2020 Jan 28"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 30-10-2024