Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSpecific control of endogenous cCF10 pheromone by a conserved domain of the pCF10-encoded regulatory protein PrgY in Enterococcus faecalis    Next AbstractUrine as a biological modality for colorectal cancer detection »

Medicina (Kaunas)


Title:The Use of Selected Ion Flow Tube-Mass Spectrometry Technology to Identify Breath Volatile Organic Compounds for the Detection of Head and Neck Squamous Cell Carcinoma: A Pilot Study
Author(s):Chandran D; Ooi EH; Watson DI; Kholmurodova F; Jaenisch S; Yazbeck R;
Address:"Discipline of Surgery, College of Medicine and Public Health, Flinders University, Adelaide 5042, Australia. dhinac20@gmail.com. Flinders Centre for Innovation in Cancer, Flinders University, Adelaide 5042, South Australia. dhinac20@gmail.com. Discipline of Surgery, College of Medicine and Public Health, Flinders University, Adelaide 5042, Australia. eooi.entsurgery@gmail.com. Flinders Centre for Innovation in Cancer, Flinders University, Adelaide 5042, South Australia. eooi.entsurgery@gmail.com. Discipline of Surgery, College of Medicine and Public Health, Flinders University, Adelaide 5042, Australia. david.watson@flinders.edu.au. Flinders Centre for Innovation in Cancer, Flinders University, Adelaide 5042, South Australia. david.watson@flinders.edu.au. Flinders Center for Epidemiology and Biostatistics, Flinders University, Adelaide 5042, South Australia. feruza.kholmurodova@flinders.edu.au. Discipline of Surgery, College of Medicine and Public Health, Flinders University, Adelaide 5042, Australia. simone.jaenisch@flinders.edu.au. Flinders Centre for Innovation in Cancer, Flinders University, Adelaide 5042, South Australia. simone.jaenisch@flinders.edu.au. Discipline of Surgery, College of Medicine and Public Health, Flinders University, Adelaide 5042, Australia. roger.yazbek@flinders.edu.au. Flinders Centre for Innovation in Cancer, Flinders University, Adelaide 5042, South Australia. roger.yazbek@flinders.edu.au"
Journal Title:Medicina (Kaunas)
Year:2019
Volume:20190625
Issue:6
Page Number: -
DOI: 10.3390/medicina55060306
ISSN/ISBN:1648-9144 (Electronic) 1010-660X (Print) 1010-660X (Linking)
Abstract:"Background: Head and neck squamous cell carcinoma (HNSCC) is the sixth most common form of cancer worldwide, with approximately 630,000 new cases diagnosed each year. The development of low-cost and non-invasive tools for the detection of HNSCC using volatile organic compounds (VOCs) in the breath could potentially improve patient care. The aim of this study was to investigate the feasibility of selected ion flow tube mass spectrometry (SIFT-MS) technology to identify breath VOCs for the detection of HNSCC. Materials and Methods: Breath samples were obtained from HNSCC patients (N = 23) and healthy volunteers (N = 21). Exhaled alveolar breath samples were collected into FlexFoil((R)) PLUS (SKC Limited, Dorset, UK) sampling bags from newly diagnosed, histologically confirmed, untreated patients with HNSCC and from non-cancer participants. Breath samples were analyzed by Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) (Syft Technologies, Christchurch, New Zealand) using Selective Ion Mode (SIM) scans that probed for 91 specific VOCs that had been previously reported as breath biomarkers of HNSCC and other malignancies. Results: Of the 91 compounds analyzed, the median concentration of hydrogen cyanide (HCN) was significantly higher in the HNSCC group (2.5 ppb, 1.6-4.4) compared to the non-cancer group (1.1 ppb, 0.9-1.3; Benjamini-Hochberg adjusted p < 0.05). A receiver operating curve (ROC) analysis showed an area under the curve (AUC) of 0.801 (95% CI, 0.65952-0.94296), suggesting moderate accuracy of HCN in distinguishing HNSCC from non-cancer individuals. There were no statistically significant differences in the concentrations of the other compounds of interest that were analyzed. Conclusions: This pilot study demonstrated the feasibility of SIFT-MS technology to identify VOCs for the detection of HNSCC"
Keywords:"Adult Biomarkers, Tumor/analysis Chi-Square Distribution Cohort Studies Female Humans Male Mass Screening/methods Mass Spectrometry/methods Middle Aged Pilot Projects Prospective Studies ROC Curve *Respiration South Australia Squamous Cell Carcinoma of He;"
Notes:"MedlineChandran, Dhinashini Ooi, Eng H Watson, David I Kholmurodova, Feruza Jaenisch, Simone Yazbeck, Roger eng Switzerland 2019/06/28 Medicina (Kaunas). 2019 Jun 25; 55(6):306. doi: 10.3390/medicina55060306"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 30-12-2024