Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Synthesis and NMR Characterization of the Prenylated Peptide, a-Factor"    Next AbstractSpecies-Specific Induction of Plant Volatiles by Two Aphid Species in Apple: Real Time Measurement of Plant Emission and Attraction of Lacewings in the Wind Tunnel »

Adv Respir Med


Title:Volatile Organic Compound Identification-Based Tuberculosis Screening among TB Suspects: A Diagnostic Accuracy Study
Author(s):Badola M; Agrawal A; Roy D; Sinha R; Goyal A; Jeet N;
Address:"Department of Health and Family Welfare, Government of Uttarakhand, Dehradun 248001, India. Department of TB & Chest, Government Doon Medical College, Dehradun 248001, India. Department of Community Medicine, Government Doon Medical College, Dehradun 248001, India. Department of General Medicine, Government Doon Medical College, Dehradun 248001, India"
Journal Title:Adv Respir Med
Year:2023
Volume:20230712
Issue:4
Page Number:301 - 309
DOI: 10.3390/arm91040024
ISSN/ISBN:2543-6031 (Electronic) 2451-4934 (Print) 2451-4934 (Linking)
Abstract:"Tuberculosis (TB) affects a third of the global population, and a large population of infected individuals still remain undiagnosed-making the visible burden only the tip of the iceberg. The detection of tuberculosis in close-proximity patients is one of the key priorities for attaining the Sustainable Development Goals (SDG) of TB elimination by 2030. With the current battery of screening tests failing to cover this need, the authors of this paper examined a simple and inexpensive point-of-care breath analyzer (TSI-3000(I)), which is based on detecting the volatile organic compounds that are emitted from infected cells and released in exhaled breath as a screening tool for the detection of TB. A single-center pilot study for assessing the diagnostic accuracy of the point-of-care Tuberculosis Breath Analyzer was conducted, and it was compared against the WHO-recommended TrueNat assay, which is a rapid molecular test and was also treated as the reference standard in this study. Of the 334 enrolled participants with TB signs/symptoms, 42.51% were TrueNat positive for Mycobacterium tuberculosis. The sensitivity of the Tuberculosis Breath Analyzer was found to be 95.7%, with a specificity of 91.3% and a ROC area of 0.935. The test kit showed considerable/significant high sensitivity and specificity as reliability indicators. The performance of the Tuberculosis Breath Analyzer tested was found to be comparable in efficiency to that of the TrueNat assay. A large cohort-based multicentric study is feasibly required to further validate and extrapolate the results of the pilot study"
Keywords:Humans *Volatile Organic Compounds Pilot Projects Reproducibility of Results Mass Screening *Tuberculosis Mycobacterium tuberculosis VOCs breath testing diagnostic accuracy study;
Notes:"MedlineBadola, Mayank Agrawal, Anurag Roy, Debabrata Sinha, Richa Goyal, Avisham Jeet, Narayan eng Switzerland 2023/07/25 Adv Respir Med. 2023 Jul 12; 91(4):301-309. doi: 10.3390/arm91040024"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 30-10-2024