Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Evaluation of a cooling/heating-assisted microextraction instrument using a needle trap device packed with aminosilica/graphene oxide nanocomposites, covalently attached to cotton"    Next AbstractFate and effects of acrolein »

Talanta


Title:Determination of linear and cyclic volatile methyl siloxanes in biogas and biomethane by solid-phase microextraction and gas chromatography-mass spectrometry
Author(s):Ghidotti M; Fabbri D; Torri C;
Address:"Interdepartmental Centre for Industrial Research 'FRAME' and Department of Chemistry 'Giacomo Ciamician', University of Bologna, Ravenna Campus, via S.Alberto 163, I-48123 Ravenna, Italy. Electronic address: michele.ghidotti2@unibo.it. Interdepartmental Centre for Industrial Research 'FRAME' and Department of Chemistry 'Giacomo Ciamician', University of Bologna, Ravenna Campus, via S.Alberto 163, I-48123 Ravenna, Italy"
Journal Title:Talanta
Year:2019
Volume:20181113
Issue:
Page Number:258 - 264
DOI: 10.1016/j.talanta.2018.11.032
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"A new method based on solid-phase microextraction (SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for the analysis of seven linear (L2 - L5) and cyclic (D3 - D5) volatile methyl siloxanes (VMS) in biogas and biomethane, directly collected into Tedlar(R) bags (Tedlar SPME) from anaerobic digesters and wastewater treatment plants. The method was employed to monitor VMS content in biomethane produced by biogas upgrading with a pilot-plant membrane unit and provided adequate limits of quantification (< 0.05?ª+mg?ª+m(-3)) to detect trace siloxane impurities. Tedlar SPME was validated against a standard procedure based on indirect sampling of gas streams with sorbent tubes followed by solvent extraction and GC-MS. Method precision (RSD) on total and individual VMS concentrations was lower than 10%, while RSD values of the standard procedure were higher than 20%. Tedlar SPME suitably revealed high VMS levels, expressed as total volatile silicon (> 1?ª+mg(Si)m(-3)), in wastewater biogas and provided a more efficient sampling of heavier VMS in comparison to the sorbent tubes method. At low values (< 0.1?ª+mg(Si)m(-3)) typical of wood waste biogas and biomethane, no statistically significant differences were observed between the two methods. Overall, Tedlar SPME simplified the analytical procedure by reducing the procedural steps, avoiding the use of solvents and demonstrated its applicability for testing the quality of biomethane as advanced biofuel"
Keywords:Automotive fuel Decamethylcyclopentasiloxane Natural gas Octamethylcyclotetrasiloxane Sewage sludge Volatile organic compounds;
Notes:"PubMed-not-MEDLINEGhidotti, Michele Fabbri, Daniele Torri, Cristian eng Netherlands 2019/01/11 Talanta. 2019 Apr 1; 195:258-264. doi: 10.1016/j.talanta.2018.11.032. Epub 2018 Nov 13"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024