Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract[Mechanism of action of pheromones in mammals]    Next Abstract"Comparative study of the adsorption performance of a multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and a Tenax TA adsorbent tube for the analysis of volatile organic compounds (VOCs)" »

J Environ Sci (China)


Title:Determining indoor air quality and identifying the origin of odour episodes in indoor environments
Author(s):Gallego E; Roca X; Perales JF; Guardino X;
Address:"Environmental Centre Laboratory, Polytechnic University of Catalonia (LCMA-UPC), Avda, Diagonal 647, E 08028 Barcelona, Spain. Lcma.info@upc.edu"
Journal Title:J Environ Sci (China)
Year:2009
Volume:21
Issue:3
Page Number:333 - 339
DOI: 10.1016/s1001-0742(08)62273-1
ISSN/ISBN:1001-0742 (Print) 1001-0742 (Linking)
Abstract:"A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) levels were detected during episodes in indoor air (1.33 +/- 1.53 mg/m3) compared to outdoor air (0.71 +/- 0.46 mg/m3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-methoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building"
Keywords:"Air Pollution, Indoor/*analysis *Environmental Monitoring/instrumentation/methods Humans *Odorants Sick Building Syndrome Volatile Organic Compounds/*analysis;"
Notes:"MedlineGallego, Eva Roca, Xavier Perales, Jose Francisco Guardino, Xavier eng Netherlands 2009/07/29 J Environ Sci (China). 2009; 21(3):333-9. doi: 10.1016/s1001-0742(08)62273-1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024