Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractRedox-Induced In Situ Growth of MnO(2) with Rich Oxygen Vacancies over Monolithic Copper Foam for Boosting Toluene Combustion    Next AbstractSpatial distribution of organic pollutants in industrial construction and demolition waste and their mutual interaction on an abandoned pesticide manufacturing plant »

J Hazard Mater


Title:"A rapid and accurate method, ventilated chamber C-history method, of measuring the emission characteristic parameters of formaldehyde/VOCs in building materials"
Author(s):Huang S; Xiong J; Zhang Y;
Address:"Department of Building Science, Tsinghua University, Beijing 100084, China"
Journal Title:J Hazard Mater
Year:2013
Volume:20130808
Issue:
Page Number:542 - 549
DOI: 10.1016/j.jhazmat.2013.08.001
ISSN/ISBN:1873-3336 (Electronic) 0304-3894 (Linking)
Abstract:"The indoor pollution caused by formaldehyde and volatile organic compounds (VOCs) emitted from building materials poses an adverse effect on people's health. It is necessary to understand and control the behaviors of the emission sources. Based on detailed mass transfer analysis on the emission process in a ventilated chamber, this paper proposes a novel method of measuring the three emission characteristic parameters, i.e., the initial emittable concentration, the diffusion coefficient and the partition coefficient. A linear correlation between the logarithm of dimensionless concentration and time is derived. The three parameters can then be calculated from the intercept and slope of the correlation. Compared with the closed chamber C-history method, the test is performed under ventilated condition thus some commonly-used measurement instruments (e.g., GC/MS, HPLC) can be applied. While compared with other methods, the present method can rapidly and accurately measure the three parameters, with experimental time less than 12h and R(2) ranging from 0.96 to 0.99 for the cases studied. Independent experiment was carried out to validate the developed method, and good agreement was observed between the simulations based on the determined parameters and experiments. The present method should prove useful for quick characterization of formaldehyde/VOC emissions from indoor materials"
Keywords:"Air Pollution, Indoor/*analysis *Construction Materials Environmental Monitoring/*methods Formaldehyde/*analysis Volatile Organic Compounds/analysis Building material C-history method Formaldehyde Indoor air quality (IAQ) Volatile organic compounds (VOCs);"
Notes:"MedlineHuang, Shaodan Xiong, Jianyin Zhang, Yinping eng Research Support, Non-U.S. Gov't Netherlands 2013/09/03 J Hazard Mater. 2013 Oct 15; 261:542-9. doi: 10.1016/j.jhazmat.2013.08.001. Epub 2013 Aug 8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024