Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOveractivation of the protein kinase C-signaling pathway suppresses the defects of cells lacking the Rho3/Rho4-GAP Rgd1p in Saccharomyces cerevisiae    Next Abstract"Response thresholds to recruitment signals and the regulation of foraging intensity in the ant Myrmica sabuleti (Hymenoptera, Formicidae)" »

Indoor Air


Title:Volatile organic compounds effective diffusion coefficients and fluxes estimation through two types of construction material
Author(s):De Biase C; Loechel S; Putzmann T; Bittens M; Weiss H; Daus B;
Address:"Department of Groundwater Remediation, UFZ - Helmholtz Centre for Environmental Research, Leipzig, Germany"
Journal Title:Indoor Air
Year:2014
Volume:20131115
Issue:3
Page Number:272 - 282
DOI: 10.1111/ina.12077
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"Accumulation of volatile organic compounds (VOCs) that migrate inside buildings from underlying contaminated soils and groundwater poses human health risks. VOCs intrusion into buildings driven only by diffusion was reproduced by a laboratory-scale experiment. Effective diffusion coefficients and fluxes of a group of selected chlorinated solvents and BTEX through two types of isolation material - that is, concrete (anhydrite screed) and geo-membrane - were estimated. The laboratory experiment indicated that the diffusive transfer of pollutants through sediments into indoor air of buildings cannot be prevented by building sealing material, but it could be attenuated to a certain degree by concrete and up to non-detectable levels by the geo-membrane. Effective diffusion coefficients through concrete and geo-membrane ranged from 3.17 x 10(-2) to 5.90 x 10(-5) cm(2) /s and from 5.47 x 10(-6) to 5.50 x 10(-8) cm(2) /s, respectively. PRACTICAL IMPLICATIONS: The vapor intrusion of volatile organic compounds (VOCs) into buildings has special relevance in human health risk assessment. Prediction of indoor air VOCs concentration by applying numerical or analytical models eventually fails due to the lack of input parameters, such as the VOCs effective diffusion coefficient through building material used as foundation or isolation material. Passive migration of VOCs from contaminated sites into indoor air through construction and isolation materials has not been extensively investigated. Our findings showed that the mass flux through building material is not negligible, but it could be reduced partly, and to a minimum, with the utilization of concrete and geo-membranes, respectively. As a result of our investigation, effective diffusion coefficients of BTEX and chlorinated solvents, as well as the correlation between specific compounds' parameters and the estimated effective diffusion coefficient, are provided"
Keywords:"Air Pollution, Indoor/*analysis *Construction Materials Diffusion Humans Volatile Organic Compounds/*chemistry Btex Benzene Chlorinated solvents Concrete Geo-membrane Vapor intrusion;"
Notes:"MedlineDe Biase, C Loechel, S Putzmann, T Bittens, M Weiss, H Daus, B eng Research Support, Non-U.S. Gov't England 2013/10/19 Indoor Air. 2014 Jun; 24(3):272-82. doi: 10.1111/ina.12077. Epub 2013 Nov 15"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024