Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract[Development of emission models for volatile organic compounds from indoor materials]    Next AbstractLiver Receptor homolog-1 Regulates Apoptosis of Bovine Ovarian Granulosa Cells by Progestogen Receptor Signaling Pathway »

Wei Sheng Yan Jiu


Title:[Investigation of key indoor air pollutants in residence in part of the cities in China]
Author(s):Xu D; Shang B; Cao Z;
Address:"Institute for Environmental Health and Related Product Safety, China CDC, Beijing 100021, China"
Journal Title:Wei Sheng Yan Jiu
Year:2007
Volume:36
Issue:4
Page Number:473 - 476
DOI:
ISSN/ISBN:1000-8020 (Print) 1000-8020 (Linking)
Abstract:"OBJECTIVE: To investigate indoor air pollution levels of total volatile organic compound (TVOC), benzene, toluene, xylene, formaldehyde, ammonia and radon in residence houses in part of the cities in China. METHOD: The residence houses decorated within 12 months were selected simple randomly. Indoor air pollutants monitoring and epidemiology investigation were carried out from May 2002 to November 2004. The location of sampling was in respiratory area. The time of sampling were 30 minutes. Tenax TA adsorption/thermal desorption/ capillary gas chromatography was used to measure the concentration of TVOC, benzene, toluene and xylene. 4-amino-3-hydrazino-5-mercapto-1, 2, 4-triazole (AHMT) spectrophotometry was used to measure the concentration of formaldehyde. Nessler's reagent colorimetric method was used to measure the concentration of ammonia. The alpha-track detector method was used for radon measurement. RESULTS: The concentration of formaldehyde, ammonia, TVOC were (0.16 +/- 0.16), (0.12 +/- 0.15) and (2.18 +/- 12.94) mg/m3 respectively. The concentrations of benzene, toluene and xylenewere (124.04 +/- 272.60), (258 .90 +/- 672.98) and (189.68 +/- 561.16) microg/m3 respectively. The arithmetical and geometric average of radon were 43.8 +/- 37.7 and 37.4 Bqm(-3) respectively. CONCLUSION: Formaldehyde, benzene, toluene, xylene and TVOC were the most important pollutants in decorated houses. The radon measurement results of 26 cities may reflect the indoor radon concentration, the rate of over standard and the pollution tendency in China. The investigation of radon pollution could be the largest scale and has the most important influence in recent 20 years in China"
Keywords:"Air Pollution, Indoor/*analysis Benzene/*analysis China Cities *Environmental Monitoring Formaldehyde/*analysis Toluene/analysis Volatile Organic Compounds/*analysis;"
Notes:"MedlineXu, Dongqun Shang, Bing Cao, Zhaojin chi Research Support, Non-U.S. Gov't China 2007/10/24 Wei Sheng Yan Jiu. 2007 Jul; 36(4):473-6"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024