Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIdentification of octanal as plant growth inhibitory volatile compound released from Heracleum sosnowskyi fruit    Next AbstractAnalytical Methods for Oxalate Quantification: The Ubiquitous Organic Anion »

Lab Chip


Title:A monolithic photonic microcantilever device for in situ monitoring of volatile compounds
Author(s):Misiakos K; Raptis I; Gerardino A; Contopanagos H; Kitsara M;
Address:"Institute of Microelectronics, NCSR 'Demokritos', 15310, Athens, Greece. misiakos@imel.demokritos.gr"
Journal Title:Lab Chip
Year:2009
Volume:20090210
Issue:9
Page Number:1261 - 1266
DOI: 10.1039/b818989g
ISSN/ISBN:1473-0197 (Print) 1473-0189 (Linking)
Abstract:"A monolithic photonic microcantilever device is presented comprising silicon light sources and detectors self-aligned to suspended silicon nitride waveguides all integrated into the same silicon chip. A silicon nitride waveguide optically links a silicon light emitting diode to a detector. Then, the optocoupler releases a localized formation of resist-silicon nitride cantilevers through e-beam lithography, dry etching and precisely controlled wet etching through a special microfluidic set-up. Fine micro-optical sensing functions are performed without the need for any off-chip optics. As the bimaterial microcantilevers are deflected by the stressed polymer film, the disrupted waveguide acts like a photonic switch. Cantilever deflections in the order of 1 A caused by thickness variations in the order of 0.005 A are detectable following changes in the physicochemical factors affecting the polymer film thickness. Such factors include the sorption of volatile compounds and through a proper set-up the response to certain vapor concentrations is monitored in real time"
Keywords:Computer-Aided Design Equipment Design Equipment Failure Analysis Micro-Electrical-Mechanical Systems/*instrumentation Microchemistry/*instrumentation Microfluidic Analytical Techniques/*instrumentation Photometry/*instrumentation Photons Reproducibility;
Notes:"MedlineMisiakos, Konstantinos Raptis, Ioannis Gerardino, Annamaria Contopanagos, Harry Kitsara, Maria eng Research Support, Non-U.S. Gov't England 2009/04/17 Lab Chip. 2009 May 7; 9(9):1261-6. doi: 10.1039/b818989g. Epub 2009 Feb 10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024