Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIn vitro cytotoxicity and morphological assessment of smoke from polymer combustion in human lung derived cells (A549)    Next AbstractBioprospecting of Essential Oil-Bearing Plants: Rapid Screening of Volatile Organic Compounds Using Headspace Bubble-in-Drop Single-Drop Microextraction for Gas Chromatography Analysis »

BMC Chem


Title:Inter-laboratory comparison of water solubility methods applied to difficult-to-test substances
Author(s):Letinski DJ; Redman AD; Birch H; Mayer P;
Address:"Toxicology and Environmental Sciences Division, ExxonMobil Biomedical Sciences, Inc., 1545 US Highway 22 East, Annandale, NJ, 08801-3059, USA. daniel.j.letinski@exxonmobil.com. Toxicology and Environmental Sciences Division, ExxonMobil Biomedical Sciences, Inc., 1545 US Highway 22 East, Annandale, NJ, 08801-3059, USA. Department of Environmental Engineering, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark"
Journal Title:BMC Chem
Year:2021
Volume:20210915
Issue:1
Page Number:52 -
DOI: 10.1186/s13065-021-00778-7
ISSN/ISBN:2661-801X (Electronic) 2661-801X (Linking)
Abstract:"Water solubility is perhaps the single most important physical-chemical property determining the environmental fate and effects of organic compounds. Its determination is particularly challenging for compounds with extremely low solubility, frequently referred to as 'difficult-to-test' substances and having solubility's generally less than 0.1 mg/L. The existing regulatory water solubility test for these compounds is the column elution method. Its applicability, however, is limited, to non-volatile solid or crystalline hydrophobic organic compounds. There currently exists no test guideline for measuring the water solubility of very hydrophobic liquid, and potentially volatile, difficult-to-test compounds. This paper describes a 'slow-stir' water solubility methodology along with results of a ring trial across five laboratories evaluating the method's performance. The slow-stir method was applied to n-hexylcyclohexane, a volatile, liquid hydrophobic hydrocarbon. In order to benchmark the inter-laboratory variability associated with the proposed slow-stir method, the five laboratories separately determined the solubility of dodecahydrotriphenylene, a hydrophobic solid compound using the existing column elution guideline. Results across the participating laboratories indicated comparable reproducibility with relative standard deviations (RSD) of 20% or less reported for each test compound - solubility method pair. The inter-laboratory RSD was 16% for n-hexylcyclohexane (mean 14 microg/L, n = 5) using the slow-stir method. For dodecahydrotriphenylene, the inter-laboratory RSD was 20% (mean 2.6 microg/L, n = 4) using the existing column elution method. This study outlines approaches that should be followed and the experimental parameters that have been deemed important for an expanded ring trial of the slow-stir water solubility method"
Keywords:Difficult-to-test Generator column Hydrophobic organics Ring test Slow-stir method Volatile Water solubility;
Notes:"PubMed-not-MEDLINELetinski, Daniel J Redman, Aaron D Birch, Heidi Mayer, Philipp eng Long-Range Research Initiative ECO38/European Chemical Industry Council/ Switzerland 2021/09/17 BMC Chem. 2021 Sep 15; 15(1):52. doi: 10.1186/s13065-021-00778-7"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024