Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBumble-bee foragers infected by a gut parasite have an impaired ability to utilize floral information    Next AbstractFunctional and physical interactions among Saccharomyces cerevisiae alpha-factor receptors »

Analyst


Title:Hyper-fast gas chromatography and single-photon ionisation time-of-flight mass spectrometry with integrated electrical modulator-based sampling for headspace and online VOC analyses
Author(s):Gehm C; Schnepel K; Czech H; Miersch T; Ehlert S; Zimmermann R;
Address:"Joint Mass Spectrometry Centre, Chair of Analytical Chemistry, University of Rostock, 18059 Rostock, Germany. hendryk.czech@uni-rostock.de"
Journal Title:Analyst
Year:2021
Volume:20210504
Issue:10
Page Number:3137 - 3149
DOI: 10.1039/d1an00114k
ISSN/ISBN:1364-5528 (Electronic) 0003-2654 (Linking)
Abstract:"We developed a novel fast gas chromatography (fastGC) instrument with integrated sampling of volatile organic compounds (VOCs) and detection by single-photon ionisation (SPI) time-of-flight mass spectrometry (TOFMS). A consumable-free electrical modulator rapidly cools down to -55 degrees C to trap VOCs and inject them on a short chromatographic column by prompt heating to 300 degrees C, followed by carrier gas exchange from air to helium. Due to the low thermal mass and optical heating, the fastGC is operated within total runtimes including cooling for 30 s and 15 s, referring to hyper-fast GC, and at a constantly increasing temperature ramp from 30 degrees C to 280 degrees C. The application of soft SPI-TOFMS allows the detection of co-eluting VOCs of different molecular compositions, which cannot be resolved by conventional GC (cGC) with electron ionisation (EI). Among other analytical figures of merit, we achieved limits of detection for toluene and p-xylene of 2 ppb and 0.5 ppb, respectively, at a signal-to-noise ratio of 3 and a linear response over a range of more than five orders of magnitude. Furthermore, we demonstrate the performance of the instrument on samples from the fields of environmental research and food science by headspace analysis of roasted coffee beans and needles from coniferous trees as well as by quasi-real-time analysis of biomass burning emissions and coffee roast gas"
Keywords:
Notes:"PubMed-not-MEDLINEGehm, Christian Schnepel, Kevin Czech, Hendryk Miersch, Toni Ehlert, Sven Zimmermann, Ralf eng England 2021/05/06 Analyst. 2021 May 21; 146(10):3137-3149. doi: 10.1039/d1an00114k. Epub 2021 May 4"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 30-12-2024