Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFemale sex pheromone and male behavioral responses of the bombycid moth Trilocha varians: comparison with those of the domesticated silkmoth Bombyx mori    Next AbstractInversion of pheromone preference optimizes foraging in C. elegans »

Indoor Air


Title:"Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information"
Author(s):Daisey JM; Angell WJ; Apte MG;
Address:"Indoor Environment Department, Berkeley, CA 94720, USA"
Journal Title:Indoor Air
Year:2003
Volume:13
Issue:1
Page Number:53 - 64
DOI: 10.1034/j.1600-0668.2003.00153.x
ISSN/ISBN:0905-6947 (Print) 0905-6947 (Linking)
Abstract:"We reviewed the literature on Indoor Air Quality (IAQ), ventilation, and building-related health problems in schools and identified commonly reported building-related health symptoms involving schools until 1999. We collected existing data on ventilation rates, carbon dioxide (CO2) concentrations and symptom-relevant indoor air contaminants, and evaluated information on causal relationships between pollutant exposures and health symptoms. Reported ventilation and CO2 data strongly indicate that ventilation is inadequate in many classrooms, possibly leading to health symptoms. Adequate ventilation should be a major focus of design or remediation efforts. Total volatile organic compounds, formaldehyde (HCHO) and microbiological contaminants are reported. Low HCHO concentrations were unlikely to cause acute irritant symptoms (<0.05 ppm), but possibly increased risks for allergen sensitivities, chronic irritation, and cancer. Reported microbiological contaminants included allergens in deposited dust, fungi, and bacteria. Levels of specific allergens were sufficient to cause symptoms in allergic occupants. Measurements of airborne bacteria and airborne and surface fungal spores were reported in schoolrooms. Asthma and 'sick building syndrome' symptoms are commonly reported. The few studies investigating causal relationships between health symptoms and exposures to specific pollutants suggest that such symptoms in schools are related to exposures to volatile organic compounds (VOCs), molds and microbial VOCs, and allergens"
Keywords:"Air Pollution, Indoor/*adverse effects Allergens Bacteria Carbon Dioxide/*analysis Child Fungi *Health Status Humans Quality Control Respiratory Tract Diseases/*etiology Risk Assessment *Schools Spores *Ventilation;"
Notes:"MedlineDaisey, J M Angell, W J Apte, M G eng Meta-Analysis Research Support, U.S. Gov't, Non-P.H.S. England 2003/03/01 Indoor Air. 2003 Mar; 13(1):53-64. doi: 10.1034/j.1600-0668.2003.00153.x"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024