Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Simple and economic syntheses of some (Z)-7- and (Z)-9-alkenyl acetates, and of (E,Z)-7,9-dodecadien-1-yl acetate, the sex pheromone of the European grapevine moth, using aleuritic acid as a common starting material"    Next Abstract"Quantification of growth-defense trade-offs in a common currency: nitrogen required for phenolamide biosynthesis is not derived from ribulose-1,5-bisphosphate carboxylase/oxygenase turnover" »

Anal Bioanal Chem


Title:Performance test of a sorbent tube sampler with respect to analyte loss in collecting biogenic volatile organic compounds
Author(s):Ullah MA; Kim KH;
Address:"Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seongdong-gu, Seoul, 133-791, South Korea"
Journal Title:Anal Bioanal Chem
Year:2015
Volume:20141119
Issue:2
Page Number:415 - 426
DOI: 10.1007/s00216-014-8258-x
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Linking)
Abstract:"The superiority of thermal desorption-gas chromatography (TD-GC) applications is well known for the analysis of biogenic volatile organic compounds (BVOC). Despite the recognition of potential biases associated with sorptive loss reaction, the interaction of reactive BVOC with a sorbent tube (ST) sampler has not been sufficiently investigated. In this study, the extent of such a loss on a sampling device was studied against the sorbent holder materials by comparing stainless steel (SS; main target) and quartz (QZ; reference). To this end, three bed STs (Tenax TA, Carbopack B, and Carbopack X) were prepared using both holding materials (SS vs. QZ). The extent of BVOC loss was then tested for each material against two different phases (liquid and vapor) of ten monoterpenes. Accordingly, the soptive loss on the SS holder ranged from 10 % (vapor) to 20 % (liquid). If a vapor phase BVOC was forced to pass through an empty SS tube, the extent of their loss increased further in a range of 21.1 % (beta-P) to 43.5 % (alpha-T). Likewise, similar loss rates (about 10 % reductions) were also observed when analyzing some environmental samples (pine needle) from the SS holder relative to QZ. Thus, a QZ tube is recommended over a SS tube to avoid sample loss in the collection of BVOC"
Keywords:"Calibration Chromatography, Gas/*instrumentation/methods Environmental Monitoring/instrumentation/methods Equipment Design Monoterpenes/analysis Pinus/chemistry Plant Components, Aerial/chemistry Quartz Specimen Handling/instrumentation/methods Steel Vola;"
Notes:"MedlineUllah, Md Ahsan Kim, Ki-Hyun eng Comparative Study Research Support, Non-U.S. Gov't Germany 2014/11/20 Anal Bioanal Chem. 2015 Jan; 407(2):415-26. doi: 10.1007/s00216-014-8258-x. Epub 2014 Nov 19"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024