Title:Organic pollutant exposure and health effects of cooking emissions on kitchen staff in food services
Author(s):Navruz-Varli S; Bilici S; Ari A; Erturk-Ari P; Ilhan MN; Gaga O;
Address:"Department of Nutrition and Dietetics, Gazi University, Ankara, Turkiye. Department of Environmental Engineering, Bolu Abant Izzet Baysal University, Bolu, Turkiye. Faculty of Medicine, Gazi University, Ankara, Turkiye. Department of Environmental Engineering, Eskisehir Technical University, Eskisehir, Turkiye"
Journal Title:Indoor Air
Year:2022
Volume:32
Issue:8
Page Number:e13093 -
DOI: 10.1111/ina.13093
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"This study was conducted to determine the exposure and health risk to cooking fumes of a total of 88 volunteer kitchen staff aged between 18 and 65 years working in five different kitchens in Ankara. Gas- and particle-phase polycyclic aromatic hydrocarbons (PAHs), and volatile organic compound (VOCs) concentrations were evaluated in the indoor air of 5 kitchens. Serum malondialdehyde (MDA) and superoxide dismutase (SOD) levels were analyzed to determine the oxidative damage as a result of the exposure to cooking fumes among the cooks and waiters. Significant positive relationships were found between serum MDA levels of the hot kitchen workers and indoor chrysene (Chr), indeno(1,2,3-c,d)pyrene (Ind), and total VOC levels. Although the carcinogenic risks estimated for the exposed population were between the acceptable/tolerable levels, the hazard quotient (HQ) estimated for the exposure to indoor benzene exceeded the safe level. The results of the study revealed that exposure to organic pollutants in indoor air may be a risk factor for the development of oxidative stress, especially in hot kitchen workers. The importance of efficient ventilation in the kitchen has been pointed out to reduce health risks caused by cooking fumes"
Keywords:"Adolescent Adult Aged *Air Pollutants/analysis *Air Pollutants, Occupational/analysis *Air Pollution, Indoor/adverse effects/analysis Cooking/methods Environmental Monitoring *Environmental Pollutants *Food Services Gases/analysis Humans Middle Aged *Occu;"
Notes:"MedlineNavruz-Varli, Semra Bilici, Saniye Ari, Akif Erturk-Ari, Pelin Ilhan, Mustafa Necmi O Gaga, Eftade eng Research Support, Non-U.S. Gov't England 2022/08/31 Indoor Air. 2022 Aug; 32(8):e13093. doi: 10.1111/ina.13093"

 