Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract[Estimation and forecast of volatile organic compounds emitted from paint uses in China]    Next Abstract"Characteristics of ozone and ozone precursors (VOCs and NOx) around a petroleum refinery in Beijing, China" »

PLoS One


Title:Influence of precision of emission characteristic parameters on model prediction error of VOCs/formaldehyde from dry building material
Author(s):Wei W; Xiong J; Zhang Y;
Address:"Department of Building Science, Tsinghua University, Beijing, China"
Journal Title:PLoS One
Year:2013
Volume:20131203
Issue:12
Page Number:e80736 -
DOI: 10.1371/journal.pone.0080736
ISSN/ISBN:1932-6203 (Electronic) 1932-6203 (Linking)
Abstract:"Mass transfer models are useful in predicting the emissions of volatile organic compounds (VOCs) and formaldehyde from building materials in indoor environments. They are also useful for human exposure evaluation and in sustainable building design. The measurement errors in the emission characteristic parameters in these mass transfer models, i.e., the initial emittable concentration (C 0), the diffusion coefficient (D), and the partition coefficient (K), can result in errors in predicting indoor VOC and formaldehyde concentrations. These errors have not yet been quantitatively well analyzed in the literature. This paper addresses this by using modelling to assess these errors for some typical building conditions. The error in C 0, as measured in environmental chambers and applied to a reference living room in Beijing, has the largest influence on the model prediction error in indoor VOC and formaldehyde concentration, while the error in K has the least effect. A correlation between the errors in D, K, and C 0 and the error in the indoor VOC and formaldehyde concentration prediction is then derived for engineering applications. In addition, the influence of temperature on the model prediction of emissions is investigated. It shows the impact of temperature fluctuations on the prediction errors in indoor VOC and formaldehyde concentrations to be less than 7% at 23+/-0.5 degrees C and less than 30% at 23+/-2 degrees C"
Keywords:"*Construction Materials Formaldehyde/*chemistry Humans *Models, Chemical Predictive Value of Tests Volatile Organic Compounds/*chemistry;"
Notes:"MedlineWei, Wenjuan Xiong, Jianyin Zhang, Yinping eng Research Support, Non-U.S. Gov't 2013/12/07 PLoS One. 2013 Dec 3; 8(12):e80736. doi: 10.1371/journal.pone.0080736. eCollection 2013"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024