Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractGenetic and epigenetic architecture of sex-biased expression in the jewel wasps Nasonia vitripennis and giraulti    Next AbstractEnhancing anaerobic digestion of waste activated sludge by pretreatment: effect of volatile to total solids »

Anal Chem


Title:Direct Analysis of Nonvolatile Chemical Compounds on Surfaces Using a Hand-Held Mass Spectrometer with Synchronized Discharge Ionization Function
Author(s):Wang X; Zhou X; Ouyang Z;
Address:"Weldon School of Biomedical Engineering, double daggerDepartment of Electrical and Computer Engineering, and section signDepartment of Chemistry, Purdue University , West Lafayette, Indiana 47907, United States"
Journal Title:Anal Chem
Year:2016
Volume:20151211
Issue:1
Page Number:826 - 831
DOI: 10.1021/acs.analchem.5b03356
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"Synchronized discharge ionization (SDI) was previously developed for hand-held mass spectrometers with discontinuous atmospheric pressure interfaces. The function of SDI has been demonstrated for analysis of volatile organic compounds in air at high sensitivity, which is attributed to the fact that ions were produced next to the ion trap mass analyzer inside the vacuum manifold. In this study, a simple sampling device was designed and fitted to a hand-held mass spectrometer to characterize its potential in direct analysis of low-volatility chemicals on surfaces. Nine chemicals of vapor pressures ranging from 10(-4) to 10(-8) Torr (at room temperature), including pesticides, illicit drugs, and explosives, were selected to evaluate and demonstrate the analytical capability of the designed system. Compounds of vapor pressures below 10(-7) Torr, such as tetryl, cocaine, and tetrahydrocannabinol (THC), have been successfully detected. Direct analysis of pesticides from fruit and explosives from a large surface area has also been demonstrated. Tandem mass analysis was performed, which helped to confirm the analyte identity as well as to improve the signal-to-noise ratio (S/N)"
Keywords:Aniline Compounds/*analysis Atmospheric Pressure Fruit/chemistry *Ion-Selective Electrodes Malus/chemistry Mass Spectrometry/*instrumentation Nitrobenzenes/*analysis Surface Properties Trinitrotoluene/*analysis Volatilization;
Notes:"MedlineWang, Xiao Zhou, Xiaoyu Ouyang, Zheng eng R01 GM106016/GM/NIGMS NIH HHS/ 1R01GM106016/GM/NIGMS NIH HHS/ Research Support, N.I.H., Extramural Research Support, U.S. Gov't, Non-P.H.S. 2015/12/01 Anal Chem. 2016 Jan 5; 88(1):826-31. doi: 10.1021/acs.analchem.5b03356. Epub 2015 Dec 11"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024