Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBehavioral and life-history evidence for interspecific competition in the larvae of two heliconian butterflies    Next AbstractThe devil is in the details »

Rapid Commun Mass Spectrom


Title:A comparison of extraction systems for plant water stable isotope analysis
Author(s):Millar C; Pratt D; Schneider DJ; McDonnell JJ;
Address:"Global Institute for Water Security, School of Environment and Sustainability, University of Saskatchewan, 11 Innovation Boulevard, Saskatoon, SK, S7N 3H5, Canada. Global Institute for Food Security, University of Saskatchewan, 110 Gymnasium Place, Saskatoon, SK, S7N 4J8, Canada"
Journal Title:Rapid Commun Mass Spectrom
Year:2018
Volume:20180527
Issue:13
Page Number:1031 - 1044
DOI: 10.1002/rcm.8136
ISSN/ISBN:1097-0231 (Electronic) 0951-4198 (Linking)
Abstract:"RATIONALE: The stable isotope ratios of water (delta(2) H and delta(18) O values) have been widely used to trace water in plants in a variety of physiological, ecohydrological, biogeochemical and hydrological studies. In such work, the analyte must first be extracted from samples, prior to isotopic analysis. While cryogenic vacuum distillation is currently the most widely used method reported in the literature, a variety of extraction-collection-analysis methods exist. A formal inter-method comparison on plant tissues has yet to be carried out. METHODS: We performed an inter-method comparison of six plant water extraction techniques: direct vapour equilibration, microwave extraction, two unique versions of cryogenic vacuum distillation, centrifugation, and high-pressure mechanical squeezing. These methods were applied to four isotopically unique plant portions (head, stem, leaf, and root crown) of spring wheat (Triticum aestivum L.). Extracted plant water was analyzed via spectrometric (OA-ICOS) and mass-based (IRMS) analysis systems when possible. Spring wheat was grown under controlled conditions with irrigation inputs of a known isotopic composition. RESULTS: The tested methods of extraction yielded markedly different isotopic signatures. Centrifugation, microwave extraction, direct vapour equilibration, and high-pressure mechanical squeezing produced water more enriched in (2) H and (18) O content. Both cryogenic vacuum distillation systems and the high-pressure mechanical squeezing method produced water more depleted in (2) H and (18) O content, depending upon the plant portion extracted. The various methods also produced differing concentrations of co-extracted organic compounds, depending on the mode of extraction. Overall, the direct vapor equilibration method outperformed all other methods. CONCLUSIONS: Despite its popularity, cryogenic vacuum distillation was outperformed by the direct vapor equilibration method in terms of limited co-extraction of volatile organic compounds, rapid sample throughput, and near instantaneous returned stable isotope results. More research is now needed with other plant species, especially woody plants, to see how far the findings from this study could be extended"
Keywords:Centrifugation/methods Chemical Fractionation/methods Deuterium/analysis Distillation/methods Mass Spectrometry/methods Microwaves Oxygen Isotopes/analysis Plant Leaves/chemistry Plant Roots/chemistry Plant Stems/chemistry Triticum/*chemistry Volatilizati;
Notes:"MedlineMillar, Cody Pratt, Dyan Schneider, David J McDonnell, Jeffrey J eng Comparative Study England 2018/04/13 Rapid Commun Mass Spectrom. 2018 Jul 15; 32(13):1031-1044. doi: 10.1002/rcm.8136. Epub 2018 May 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024