Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractA bee-line into learning and memory mechanisms    Next AbstractA multi-residue method for the simultaneous analysis in indoor dust of several classes of semi-volatile organic compounds by pressurized liquid extraction and gas chromatography/tandem mass spectrometry »

J Chromatogr A


Title:Analysis of semi-volatile organic compounds in indoor suspended particulate matter by thermal desorption coupled with gas chromatography/mass spectrometry
Author(s):Mercier F; Glorennec P; Blanchard O; Le Bot B;
Address:"EHESP School of Public Health, F-35043 Rennes, France. Fabien.Mercier@ehesp.fr"
Journal Title:J Chromatogr A
Year:2012
Volume:20120716
Issue:
Page Number:107 - 114
DOI: 10.1016/j.chroma.2012.07.025
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"People are exposed to multiple pollutants, especially indoors. In the perspective of a cumulative risk assessment, a multi-residue analytical method was developed to assess the contamination of indoor suspended particulate matter by 55 semi-volatile organic compounds (SVOCs) including musk fragrances, organochlorines (OCs), organophosphates (OPs), polycyclic aromatic hydrocarbons (PAHs), polybromodiphenylethers (PBDEs), polychlorobiphenyls (PCBs), phthalates and pyrethroids. It is based on thermal desorption (TD) coupled with gas chromatography/mass spectrometry (GC/MS). Once the thermal desorption conditions were optimized, the method was validated in terms of quantification limits and accuracy using a standard reference material (SRM 2585). Instrumental quantification limits were 10 pg (some OCs, some pyrethroids, musk fragrances, OPs, PAHs, PBDEs and PCBs), 100 pg (phthalates and other OCs) and 1000 pg (other pyrethroids) corresponding respectively to method quantification limits of 1, 10, and 100 pg/m(3) for a sampled air volume of 20 m(3). Calibration quadratic curves for ranges of 10-1000, 100-10,000, and 1000-100,000 pg, depending on the substance, exhibit determination coefficients above 0.999. Recoveries were between 61 and 96% for chlorinated pesticides, PAHs, PBDEs and PCBs present in the SRM 2585. A test of the method on indoor particulate matter samples (PM(1)(0)) collected on quartz fiber filters in French dwellings demonstrated its ability to quantify SVOCs from a small amount of PM"
Keywords:"Air Pollution, Indoor/*analysis France Gas Chromatography-Mass Spectrometry/*methods Particulate Matter/*chemistry Reproducibility of Results Sensitivity and Specificity Temperature Volatile Organic Compounds/*analysis;"
Notes:"MedlineMercier, Fabien Glorennec, Philippe Blanchard, Olivier Le Bot, Barbara eng Research Support, Non-U.S. Gov't Netherlands 2012/07/31 J Chromatogr A. 2012 Sep 7; 1254:107-14. doi: 10.1016/j.chroma.2012.07.025. Epub 2012 Jul 16"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024