Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEffect of Leaf Maturity on Host Habitat Location by the Egg-Larval Parasitoid Ascogaster reticulata    Next Abstract"Modification, by the insecticide chlorpyrifos, of the behavioral response to kairomones of a parasitoid wasp, Leptopilina boulardi" »

J Chromatogr A


Title:"Description and characterization of an on-line system for long-term measurements of isoprene, methyl vinyl ketone, and methacrolein in ambient air"
Author(s):Komenda M; Schaub A; Koppmann R;
Address:"Institut fur Chemie und Dynamik der Geosphare, Institut II: Troposphare, Forschungszentrum Julich, D-52425 Julich, Germany. m.komenda@fz-juelich.de"
Journal Title:J Chromatogr A
Year:2003
Volume:995
Issue:1-Feb
Page Number:185 - 201
DOI: 10.1016/s0021-9673(03)00518-1
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"In this work we present a detailed technical description of the system that was set up for long-term on-line measurements of isoprene and two of its major degradation products, methyl vinyl ketone and methacrolein in order to provide a better understanding of the role of forest stands as a complex source of reactive trace gases into the troposphere and to elucidate the role of forests as chemical reactors. Volatile organic compounds (VOCs) are preconcentrated on cartridges containing a package of two solid adsorbents (Tenax TA and Carbopack X). Ozone removal is performed prior to sampling by titration with nitrogen monoxide. For the calibration and characterization of the system, a diffusion source was built to produce standard gas mixtures of up to 16 different compounds with mixing ratios at tens ppt (parts per trillion) level mixing ratios and high accuracy. The developed system allows a reliable quantification of these VOCs (detection limit approximately 10 ppt, reproducibility approximately 5%) with a high temporal resolution (approximately 30 min) and has proven to be stable and run automatically without major maintainence"
Keywords:"Acrolein/analogs & derivatives/*analysis Air Pollutants/*analysis Butadienes/*analysis Butanones/*analysis Calibration Chromatography, Gas/*instrumentation Hemiterpenes/*analysis Pentanes/*analysis Sensitivity and Specificity Volatilization;"
Notes:"MedlineKomenda, M Schaub, A Koppmann, R eng Research Support, Non-U.S. Gov't Netherlands 2003/06/13 J Chromatogr A. 2003 May 2; 995(1-2):185-201. doi: 10.1016/s0021-9673(03)00518-1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024