« Previous AbstractAddition of volatile sulfur compounds to yeast at the early stages of fermentation reveals distinct biological and chemical pathways for aroma formation    Next AbstractAnalyte and matrix evaporability - key players of low-temperature plasma ionization for ambient mass spectrometry »

PLoS One


Title:Electrospray Ionization Efficiency Is Dependent on Different Molecular Descriptors with Respect to Solvent pH and Instrumental Configuration
Author(s):Kiontke A; Oliveira-Birkmeier A; Opitz A; Birkemeyer C;
Address:"Institute of Analytical Chemistry, University of Leipzig, Linnestr., Leipzig, Germany. Institute of Linguistics, University of Leipzig, Beethovenstr., Leipzig, Germany"
Journal Title:PLoS One
Year:2016
Volume:20161201
Issue:12
Page Number:e0167502 -
DOI: 10.1371/journal.pone.0167502
ISSN/ISBN:1932-6203 (Electronic) 1932-6203 (Linking)
Abstract:"Over the past decades, electrospray ionization for mass spectrometry (ESI-MS) has become one of the most commonly employed techniques in analytical chemistry, mainly due to its broad applicability to polar and semipolar compounds and the superior selectivity which is achieved in combination with high resolution separation techniques. However, responsiveness of an analytical method also determines its suitability for the quantitation of chemical compounds; and in electrospray ionization for mass spectrometry, it can vary significantly among different analytes with identical solution concentrations. Therefore, we investigated the ESI-response behavior of 56 nitrogen-containing compounds including aromatic amines and pyridines, two compound classes of high importance to both, synthetic organic chemistry as well as to pharmaceutical sciences. These compounds are increasingly analyzed employing ESI mass spectrometry detection due to their polar, basic character. Signal intensities of the peaks from the protonated molecular ion (MH+) were acquired under different conditions and related to compound properties such as basicity, polarity, volatility and molecular size exploring their quantitative impact on ionization efficiency. As a result, we found that though solution basicity of a compound is the main factor initially determining the ESI response of the protonated molecular ion, other factors such as polarity and vaporability become more important under acidic solvent conditions and may nearly outweigh the importance of basicity under these conditions. Moreover, we show that different molecular descriptors may become important when using different types of instruments for such investigations, a fact not detailed so far in the available literature"
Keywords:"*Hydrogen-Ion Concentration Nitrogen/chemistry Organic Chemicals/chemistry Solutions *Solvents/chemistry Spectrometry, Mass, Electrospray Ionization/*methods/standards;"
Notes:"MedlineKiontke, Andreas Oliveira-Birkmeier, Ariana Opitz, Andreas Birkemeyer, Claudia eng 2016/12/03 PLoS One. 2016 Dec 1; 11(12):e0167502. doi: 10.1371/journal.pone.0167502. eCollection 2016"

 