Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPromoting Ex-Solution from Metal-Organic-Framework-Mediated Oxide Scaffolds for Highly Active and Robust Catalysts    Next AbstractResponse ofMatsucoccus thunbergianae males to synthetic sex pheromone and its utilization for monitoring the spread of infestation »

Int J Environ Res Public Health


Title:A Study of the Plan and Performance Evaluation Method of an 8-m(3) Chamber Using Ventilation Experiments and Numerical Analyses
Author(s):Park S; Park S; Seo J;
Address:"Department of Industry-Academic Cooperation Foundation, Kookmin University, 77, Jeongneung-ro, Seongbuk-gu, Seoul 02707, Korea. Department of Architecture, Graduated School, Kookmin University, 77, Jeongneung-ro, Seongbuk-gu, Seoul 02707, Korea. School of Architecture, Kookmin University, 77, Jeongneung-ro, Seongbuk-gu, Seoul 02707, Korea"
Journal Title:Int J Environ Res Public Health
Year:2022
Volume:20221019
Issue:20
Page Number: -
DOI: 10.3390/ijerph192013556
ISSN/ISBN:1660-4601 (Electronic) 1661-7827 (Print) 1660-4601 (Linking)
Abstract:"With increases in the time spent on indoor activities, the interests and technological demands regarding indoor air quality (IAQ) have also increased. Indoor air pollution is often caused by furniture or construction materials and chemical substances, such as volatile organic compounds (VOCs). As a way to remove such pollutants, efforts have been made to promote the management of indoor air quality through emission experiments. To conduct an experiment, such as the pollutant emission experiment involving substances harmful to the human body, a chamber to control various factors should be developed. By using such chambers, experimental variables can be minimized, quantitative analyses may be conducted, and the basic theory may be discussed. When the chamber is installed, it is not easy to change the existing installed conditions. Therefore, it is necessary to review feasibility with an accurate design. However, there is limited research on both how to quantitatively design the chamber and evaluate it. Therefore, this study investigates suitable chamber design methods and performance through ventilation performance evaluation to discuss potential development methods. In the chamber design step, a computational fluid dynamics (CFD) analysis was performed to estimate the ventilation efficiency according to the inlet and outlet positions to develop an 8-m(3) chamber. Next, a ventilation experiment was performed using the tracer gas method for the performance evaluation, while the chamber interior airflow was simulated based on the CFD analysis. In a ventilation experiment using a tracer gas, the variation in gas density leads to concentration imbalance; as a result of concentration imbalance at each point, errors may occur in ventilation efficiency depending on the measurement point, causing the accuracy of the performance evaluation to fall. An attempt was made to resolve this problem by performing the ventilation experiment with a ceiling fan. The result indicated that the performance evaluation could be conducted without altering ventilation efficiency, coinciding with the CFD analysis result. Furthermore, when the concentration field was examined according to time in the CFD analysis, uniform concentration of chamber interior air allowed the ventilation efficiency to be calculated irrespective of the measurement point. Based on the findings, this study suggests a quantitative method of performance evaluation with an experiment in an 8-m(3) chamber and a concurrent CFD analysis"
Keywords:"Humans *Volatile Organic Compounds/analysis Ventilation/methods *Air Pollution, Indoor/analysis Hydrodynamics *Environmental Pollutants/analysis 8-m3 chamber carbon dioxide (CO2) computational fluid dynamics (CFD) performance evaluation ventilation effici;"
Notes:"MedlinePark, Seonghyun Park, Seongwoo Seo, Janghoo eng 2021R1A2B5B02001469/National Research Foundation of Korea/ 2021R1C1C2003596/National Research Foundation of Korea/ Research Support, Non-U.S. Gov't Switzerland 2022/10/28 Int J Environ Res Public Health. 2022 Oct 19; 19(20):13556. doi: 10.3390/ijerph192013556"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024