Surg Endosc


Title:Surgical smoke may be a biohazard to surgeons performing laparoscopic surgery
Author(s):Choi SH; Kwon TG; Chung SK; Kim TH;
Address:"Department of Urology, School of Medicine, Kyungpook National University Medical Center, Hakjeong-dong, Buk-gu, Daegu, 702-210, Korea, skhwan@gmail.com"
Journal Title:Surg Endosc
Year:2014
Volume:20140226
Issue:8
Page Number:2374 - 2380
DOI: 10.1007/s00464-014-3472-3
ISSN/ISBN:1432-2218 (Electronic) 0930-2794 (Linking)
Abstract:"BACKGROUND: Surgical smoke production is inevitable during surgical procedures. Although many workplaces have adopted smoke-free environments, healthcare workers, especially surgeons, continue to be exposed to surgical smoke. METHODS: From February 2013 to March 2013, a total of 20 patients underwent transperitoneal laparoscopic nephrectomy for renal cell carcinoma. A 5-L gas sample was collected 30 min after the electrocautery device was first used and was analyzed by gas chromatography and mass spectrometry. Cancer risk was calculated for carcinogenic compounds and hazard quotient was calculated for noncarcinogenic compounds using US Environmental Protection Agency guidelines. RESULTS: Twenty patients with a median age of 57.5 years were enrolled in the study. Eighteen volatile organic compounds were detected by Japanese indoor air standards mix analysis. The cancer risks were ethanol, 5.10 x 10(-5) +/- 6.35 x 10(-5); 1,2-dichloroethane, 4.75 x 10(-3) +/- 7.42 x 10(-4); benzene, 1.09 x 10(-3) +/- 4.33 x 10(-4); ethylbenzene, 2.87 x 10(-5) +/- 1.32 x 10(-5); and styrene, 2.94 x 10(-6) +/- 1.16 x 10(-6). The hazard quotients were acetone, 1.88 x 10(-2) +/- 7.63 x 10(-3); hexane, 1.48 x 10(-1) +/- 8.70 x 10(-2); benzene, 4.66 +/- 1.85; toluene, 2.61 x 10(-2) +/- 7.23 x 10(-3); p-xylene, 1.81 x 10(-1) +/- 6.45 x 10(-2); o-xylene, 2.40 x 10(-2) +/- 3.33 x 10(-2); and styrene, 5.15 x 10(-3) +/- 2.03 x 10(-3). CONCLUSIONS: For five carcinogenic compounds detected, the cancer risk was greater than negligible. For 1,2-dichloroethane and benzene, the risk was classified as unacceptable. Analysis of noncarcinogenic compounds showed that risk reduction measures are needed for benzene. Even though surgical smoke is not an immediate health hazard, operating room personnel should be aware of the potential long-term health risks associated with exposure"
Keywords:"Acetone/analysis Aged Air Pollutants, Occupational/chemistry Benzene/analysis Benzene Derivatives/analysis Carcinogens/analysis Ethanol/analysis Ethylene Dichlorides/analysis Female Gas Chromatography-Mass Spectrometry Hazardous Substances/analysis Hexane;"
Notes:"MedlineChoi, Seock Hwan Kwon, Tae Gyun Chung, Sung Kwang Kim, Tae-Hwan eng Research Support, Non-U.S. Gov't Germany 2014/02/27 Surg Endosc. 2014 Aug; 28(8):2374-80. doi: 10.1007/s00464-014-3472-3. Epub 2014 Feb 26"

 