Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractTiO(2)-based catalytic systems for the treatment of airborne aromatic hydrocarbons    Next AbstractA timing sex-pheromone trap with special reference to codling moth collections »

Soft Matter


Title:Strain-enhanced sensitivity of polymeric sensors templated from cholesteric liquid crystals
Author(s):Batir O; Bat E; Bukusoglu E;
Address:"Department of Chemical Engineering, Middle East Technical University, Dumlupinar Bulvari No: 1, Cankaya, Ankara 06800, Turkey. emrebuk@metu.edu.tr"
Journal Title:Soft Matter
Year:2020
Volume:16
Issue:29
Page Number:6794 - 6802
DOI: 10.1039/d0sm00905a
ISSN/ISBN:1744-6848 (Electronic) 1744-683X (Linking)
Abstract:"Detection of volatile organic compounds (VOCs) is an important issue due to their harmful impact on human health. In this study, we aimed at enhancing the sensitivity of the anisotropic polymeric films templated from cholesteric liquid crystals (CLCs) in the identification of VOCs at concentrations on the order of 100 ppm. To increase sensitivity, we introduced negative strain to the films in the direction parallel to the helical axis and evaluated its effect on the sensitivity. Specifically, we used LC mixtures of reactive [4-(3-acryloyoxypropyloxy)benzoic acid 2-methyl-1,4-phenylene ester (RM257)], nonreactive E7 mesogen and chiral dopant [4-((1-methylheptyloxycarbonyl)phenyl-4-hexyloxybenzoate) (S-811)] to synthesize CLC-templated polymeric films with programmed strain profiles using a curved wedge cell, and measured their response against a range of toluene vapor concentrations. Based on the obtained results, we demonstrated a relationship between the negative strain in the cholesteric pitch and the sensitivity of the sensor based on spacial responses evaluated from the change in coloring of the film. Our results showed that negative strain helps to increase the sensitivity of the sensors up to 15 times compared to their unstrained counterparts. Moreover, 90% of the equilibrium response is achieved in less than one minute of exposure which offers rapid diagnosis of VOCs. Our tests for the reversibility of the sensors showed that the CLC-templated polymeric films can be used multiple times without a significant loss of sensitivity"
Keywords:
Notes:"PubMed-not-MEDLINEBatir, Ozge Bat, Erhan Bukusoglu, Emre eng England 2020/07/07 Soft Matter. 2020 Jul 29; 16(29):6794-6802. doi: 10.1039/d0sm00905a"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024