Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIdentification of Exhaled Metabolites in Children with Cystic Fibrosis    Next Abstract"Identification of volatile compounds used in host location by the black bean aphid, Aphis fabae" »

Sensors (Basel)


Title:Hybrid Sol-Gel Surface-Enhanced Raman Sensor for Xylene Detection in Solution
Author(s):Weber V; Brigo L; Brusatin G; Mattei G; Pedron D; Pilot R; Signorini R;
Address:"Department of Chemical Science, University of Padua, Via Marzolo 1, I-35131 Padova, Italy. Department of Industrial Engineering, University of Padua, Via Marzolo 9, I-35131 Padova, Italy. Department of Physics and Astronomy 'Galileo Galilei', University of Padua, Via Marzolo 8, I-35131 Padova, Italy. Consorzio INSTM, Via G. Giusti 12, I-50121 Firenze, Italy"
Journal Title:Sensors (Basel)
Year:2021
Volume:20211127
Issue:23
Page Number: -
DOI: 10.3390/s21237912
ISSN/ISBN:1424-8220 (Electronic) 1424-8220 (Linking)
Abstract:"This paper reports on the fabrication and characterization of a plasmonic/sol-gel sensor for the detection of aromatic molecules. The sol-gel film was engineered using polysilsesquioxanes groups to capture the analyte, through pi-pi interaction, and to concentrate it close to the plasmonic surface, where Raman amplification occurs. Xylene was chosen as an analyte to test the sensor. It belongs to the general class of volatile organic compounds and can be found in water or in the atmosphere as pollutants released from a variety of processes; its detection with SERS is typically challenging, due to its low affinity toward metallic surfaces. The identification of xylene was verified in comparison with that of other aromatic molecules, such as benzene and toluene. Investigations were carried out on solutions of xylene in cyclohexane, using concentrations in the range from 0 to 800 mM, to evaluate the limit of detection (LOD) of about 40 mM"
Keywords:"Benzene/analysis Limit of Detection Toluene/analysis *Water Pollutants, Chemical/analysis *Xylenes SERS sensor nanostructures sol-gel film xylene;"
Notes:"MedlineWeber, Verena Brigo, Laura Brusatin, Giovanna Mattei, Giovanni Pedron, Danilo Pilot, Roberto Signorini, Raffaella eng Switzerland 2021/12/11 Sensors (Basel). 2021 Nov 27; 21(23):7912. doi: 10.3390/s21237912"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024