Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAttraction of Myzus persicae (Hemiptera: Aphididae) to Volatiles Emitted From the Entomopathogenic Fungus Beauveria bassiana    Next AbstractNon-targeted GC/MS analysis of exhaled breath samples: Exploring human biomarkers of exogenous exposure and endogenous response from professional firefighting activity »

J Chromatogr A


Title:Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters
Author(s):Geer Wallace MA; Pleil JD; Mentese S; Oliver KD; Whitaker DA; Fent KW;
Address:"U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, Research Triangle Park, NC, USA. U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, Research Triangle Park, NC, USA. Electronic address: pleil@email.unc.edu. Department of Environmental Engineering, Canakkale Onsekiz Mart University, Merkez, Canakkale, Turkey(1). Division of Surveillance, Hazard Evaluations, and Field Studies, National Institute for Occupational Safety and Health (NIOSH), Cincinnati, OH, USA"
Journal Title:J Chromatogr A
Year:2017
Volume:20170728
Issue:
Page Number:114 - 124
DOI: 10.1016/j.chroma.2017.07.082
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Print) 0021-9673 (Linking)
Abstract:"Traditionally, gas chromatography-mass spectrometry (GC/MS) analysis has used a targeted approach called selected ion monitoring (SIM) to quantify specific compounds that may have adverse health effects. Due to method limitations and the constraints of preparing duplicate samples, the information that could be obtained from separately collecting the full scan chromatogram of the sample has often been sacrificed. However, the hybrid technique called synchronous SIM/scan mode alternates between the two acquisition modes, maintaining the accuracy and sensitivity of SIM for targeted analysis while also providing the full scan chromatogram for discovery of non-target compounds. This technology was assessed using calibration data and real-world breath samples from a joint EPA/NIOSH collaboration that investigated the safety of firefighters' protective gear during controlled structure burns. Collecting field samples is costly and must be performed strategically to ensure that time points and replicates are accurate and representative of the intended population. This is difficult to accomplish with firefighters who are working under volatile conditions. The synchronous SIM/scan method decreases the number of field samples that need to be collected by half and reduces error in trying to recreate time points since a breath sample from a single sorbent tube can be used to collect both the SIM and scan data simultaneously. As a practical demonstration of the method, we investigate thirty-six firefighter breath samples, document organic compounds of interest, and identify additional non-target compounds"
Keywords:Breath Tests/instrumentation/*methods Calibration *Firefighters Gas Chromatography-Mass Spectrometry/*methods Humans Organic Chemicals/analysis Automated thermal desorption (ATD) Breath research Gas chromatography-mass spectrometry (GC/MS) Polyaromatic hy;
Notes:"MedlineGeer Wallace, M Ariel Pleil, Joachim D Mentese, Sibel Oliver, Karen D Whitaker, Donald A Fent, Kenneth W eng EPA999999/Intramural EPA/ Netherlands 2017/08/26 J Chromatogr A. 2017 Sep 22; 1516:114-124. doi: 10.1016/j.chroma.2017.07.082. Epub 2017 Jul 28"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 19-11-2024