Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPhysicochemical parameters combined flash GC e-nose and artificial neural network for quality and volatile characterization of vinegar with different brewing techniques    Next AbstractSingle-Shot Object Detection via Feature Enhancement and Channel Attention »

Opt Express


Title:Pre-compressed polymer cholesteric liquid crystal based optical fiber VOC sensor with high stability and a wide detection range
Author(s):Li Y; Yin Z; Luo D;
Address:
Journal Title:Opt Express
Year:2022
Volume:30
Issue:18
Page Number:32822 - 32832
DOI: 10.1364/OE.470518
ISSN/ISBN:1094-4087 (Electronic) 1094-4087 (Linking)
Abstract:"As the concentration of VOC gases is very high in organic chemical reactions, in order to ensure the safety and accuracy of the experiment, it is very important to develop a gas sensor with a wide detection range. Exploring the mechanism and law of photonic bandgap (PBG) shift after absorption of volatile organic compounds (VOCs) vapors are two basic premises of resolving the PCLC for gas detection with a wide measurement range and stability. Herein, the PCLC films doped with different concentrations of polymer are used for acetone vapor detection, and the shift law of the PBG position is analyzed. As the increase of the detected gas concentration, the intractable problem is that the PBG position of PCLC exhibits red- and blue-shifts successively. Particularly, the pre-compressed technique is highly important for development of a high-performance PCLC based fiber probe, which is crucial for effectively solving the bottleneck problem mentioned. It enables detection of a wide range of acetone vapor concentration from 0 ppm to 50x10(4) ppm, and the corresponding mean sensitivity of 0.23 pm/ppm. In addition, the thermal crosstalk is generally negligible at temperature below 40 degrees C. Therefore, it is a breakthrough that the described technique not only effectively enhances the stability and robustness of the PCLC fiber probe for VOC vapor detection, but also improves its sensitivity and detection range. The pre-compressed technique provides a novel avenue for fabrication of other PCLC-based devices"
Keywords:
Notes:"PubMed-not-MEDLINELi, Yong Yin, Zhen Luo, Dan eng 2022/10/16 Opt Express. 2022 Aug 29; 30(18):32822-32832. doi: 10.1364/OE.470518"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 06-11-2024