Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPressurised liquid extraction of volatile compounds in coffee bean    Next AbstractVolatile and Sensory Profiles of Algerian Extra-Virgin Olive Oil from Souidi and Zeletni Cultivars »

Talanta


Title:Simultaneous quantitation of volatile compounds in citrus beverage through stir bar sorptive extraction coupled with thermal desorption-programmed temperature vaporization
Author(s):Cheong MW; Lee JY; Liu SQ; Zhou W; Nie Y; Kleine-Benne E; Curran P; Yu B;
Address:"Food Science and Technology Programme, c/o Department of Chemistry, National University of Singapore, Science Drive 2, Singapore 117543, Singapore"
Journal Title:Talanta
Year:2013
Volume:20130108
Issue:
Page Number:118 - 126
DOI: 10.1016/j.talanta.2012.12.034
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"Due to disparate concentrations and physiochemical properties of analytes, difficulties in terms of sensitivity and reproducibility are commonly encountered in flavour analysis. In this study, we attempted to improve the performance of stir bar sorptive extraction coupled with thermal desorption and programmed temperature vaporization (SBSE-TD-PTV) based on a model citrus beverage. Through response surface methodology, thermal desorption conditions (i.e. desorption flow, thermal desorption time and cryofocusing temperature) were optimised based on constrained optimisation. Solute discrimination during injection was alleviated by normalising the variability of peak responses of different analytes. In addition, the effects of extraction conditions (i.e. ionic strength, stirring speed, extraction time, temperature and pH) were also investigated using partial factorial design. The obtained method showed high precision and good linearity over the concentration ranged from 0.10 to 20.00 mug L(-1) with the correlation coefficients higher than 0.991 for most of the selected chemicals, except indole. The limit of detection ranged from 0.03 to 3.89 mug L(-1). Hence, our results indicated that through the systematic study, SBSE-TD-PTV method became much less solute discriminative and more reliable to quantitate complex analytes"
Keywords:Beverages/*analysis Chemical Fractionation/*methods Citrus/*chemistry Flavoring Agents/analysis Food Analysis/*methods Gas Chromatography-Mass Spectrometry/*methods Reproducibility of Results Temperature Volatile Organic Compounds/*analysis Volatilization;
Notes:"MedlineCheong, Mun Wai Lee, Justin Yong Kiang Liu, Shao Quan Zhou, Weibiao Nie, Yunyun Kleine-Benne, Eike Curran, Philip Yu, Bin eng Validation Study Netherlands 2013/04/20 Talanta. 2013 Mar 30; 107:118-26. doi: 10.1016/j.talanta.2012.12.034. Epub 2013 Jan 8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024