Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractNon-Invasive Lung Cancer Diagnostics through Metabolites in Exhaled Breath: Influence of the Disease Variability and Comorbidities    Next AbstractA denuder-filter sampling technique for the detection of gas and particle phase carbonyl compounds »

Environ Pollut


Title:An experimental set up of a PAH vapour generator and its use to test an annular denuder
Author(s):Temime B; Francois S; Monod A; Wortham H;
Address:"Laboratoire Chimie et Environnement, Universite de Provence, Marseille, France"
Journal Title:Environ Pollut
Year:2002
Volume:120
Issue:3
Page Number:609 - 616
DOI: 10.1016/s0269-7491(02)00193-8
ISSN/ISBN:0269-7491 (Print) 0269-7491 (Linking)
Abstract:"The aim of this work is to develop and test a dynamic gas generator for semi-volatile organic compounds (SVOC). A single compound, naphthalene, is used as a surrogate PAH to test the system. The dynamic generation of PAH is based on the permeation technique [Analyst 106 (1981) 817; Am. Ind. Hyg. Assoc. J. 38 (1977) 712]. Monitoring the temperature and measuring the mass of PAH present in the permeation chamber every 48 h gives a direct measurement of the sublimation rate of the PAH. Knowing the flow rate, gives an accurate value of the concentration of PAH from the generator. It was found stable over a period of time under constant operating conditions. This concentration is diluted down to between 0.3 and 30 ppbv by a controlled flow of pure air. The diluting airflow is a mixture of dry and wet air, making it possible to control the relative humidity of the flow from the generator as well as its concentration in PAH. We used this generator to calibrate an annular denuder tube, based on the study by Gundel et al. [Atmos. Environ. 29 (1995) 1719]. Although this technique has been shown to be artefact-free for sampling gaseous PAH [Polycyclic Aromatic Compounds 9 (1996) 67; Atmos. Environ. 28 (1994) 3083], its trapping efficiency still depends on environmental parameters (temperature, relative humidity and sampling duration). Accordingly, we used our generator to calibrate a single annular denuder under controlled conditions (T degrees C, HR%, CPAH, sampling duration). The trapping efficiency of the denuder was calculated by two independent methods. Firstly, by comparing the amount trapped on a denuder with the measured mass sublimated in the generator. Secondly, by putting two denuders in series and comparing the mass collected on the first and the second tube. These two methods gave similar results, within the 10% relative uncertainties of both methods. The first results obtained show that, in environmental conditions, the efficiency ranges between 90 and 100%"
Keywords:Environmental Monitoring/*instrumentation Equipment Design *Polycyclic Aromatic Hydrocarbons;
Notes:"MedlineTemime, Brice Francois, Stephanie Monod, Anne Wortham, Henri eng Validation Study England 2002/11/22 Environ Pollut. 2002; 120(3):609-16. doi: 10.1016/s0269-7491(02)00193-8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024