Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBacterial volatiles induce systemic resistance in Arabidopsis    Next AbstractComparative studies on toluene removal and pressure drop in biofilters using different packing materials »

Ecotoxicol Environ Saf


Title:Measuring the quantity of harmful volatile organic compounds inhaled through masks
Author(s):Ryu H; Kim YH;
Address:"Department of Environment and Energy, Jeonbuk National University, 567 Baekje-daero, Deokjin, Jeonju, Jeollabukdo 54896, Republic of Korea. Department of Environment and Energy, Jeonbuk National University, 567 Baekje-daero, Deokjin, Jeonju, Jeollabukdo 54896, Republic of Korea; School of Civil, Environmental, Resources and Energy Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin, Jeonju, Jeollabukdo 54896, Republic of Korea; Soil Environment Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin, Jeonju, Jeollabukdo 54896, Republic of Korea. Electronic address: ykim84@jbnu.ac.kr"
Journal Title:Ecotoxicol Environ Saf
Year:2023
Volume:20230418
Issue:
Page Number:114915 -
DOI: 10.1016/j.ecoenv.2023.114915
ISSN/ISBN:1090-2414 (Electronic) 0147-6513 (Print) 0147-6513 (Linking)
Abstract:"An increase in the concentration of environmental particulate matter and the spread of the COVID-19 virus have dramatically increased our time spent wearing masks. If harmful chemicals are released from these masks, there may be harmful effects on human health. In this study, the concentration of volatile organic compounds (VOCs) emitted from some commonly used masks was assessed qualitatively and quantitatively under diverse conditions (including different mask material types, time between opening the product and wearing, and mask temperature). In KF94 masks, 1-methoxy-2-propanol (221 +/- 356 microg m(-3)), N,N-dimethylacetamide (601 +/- 450 microg m(-3)), n-hexane (268 +/- 349 microg m(-3)), and 2-butanone (160 +/- 244 microg m(-3)) were detected at concentrations 22.9-147 times higher than those found in masks made from other materials, such as cotton and other functional fabrics. In addition, in KF94 masks, the total VOC (TVOC) released amounted to 3730 +/- 1331 microg m(-3), about 14 times more than that released by the cotton masks (267.5 +/- 51.6 microg m(-3)). In some KF94 masks, TVOC concentration reached over 4000 microg m(-3), posing a risk to human health (based on indoor air quality guidelines established by the German Environment Agency). Notably, 30 min after KF94 masks were removed from their packaging, TVOC concentrations decreased by about 80% from their initial levels to 724 +/- 5.86 microg m(-3); furthermore, 6 h after removal, TVOC concentrations were found to be less than 200 microg m(-3). When the temperature of the KF94 masks was raised to 40 (o)C, TVOC concentrations increased by 119-299%. Since the types and concentrations of VOCs that will be inhaled by mask wearers vary depending on the mask use conditions, it is necessary to comply with safe mask wearing conditions"
Keywords:"Humans *Volatile Organic Compounds/analysis Masks *covid-19 *Air Pollution, Indoor/analysis Particulate Matter Environmental Monitoring Kf94 Mask Total volatile organic compound;"
Notes:"MedlineRyu, Hajoo Kim, Yong-Hyun eng Netherlands 2023/04/20 Ecotoxicol Environ Saf. 2023 May; 256:114915. doi: 10.1016/j.ecoenv.2023.114915. Epub 2023 Apr 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024