Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOccurrence of chlorinated volatile organic compounds (VOCs) in a sanitary sewer system: Implications for assessing vapor intrusion alternative pathways    Next AbstractEffects of mutations in the N terminal region of the yeast G protein alpha-subunit Gpa1p on signaling by pheromone receptors »

Ground Water Monit Remediat


Title:MODELING FATE AND TRANSPORT OF VOLATILE ORGANIC COMPOUNDS (VOCs) INSIDE SEWER SYSTEMS
Author(s):Roghani M; Li Y; Rezaei N; Robinson A; Shirazi E; Pennell KG;
Address:"University of Kentucky, College of Engineering, Department of Civil Engineering"
Journal Title:Ground Water Monit Remediat
Year:2021
Volume:20210412
Issue:2
Page Number:112 - 121
DOI: 10.1111/gwmr.12449
ISSN/ISBN:1069-3629 (Print) 1745-6592 (Electronic) 1069-3629 (Linking)
Abstract:"Hazardous waste site investigations have shown that volatile organic compounds (VOCs) can be transported via sewer pipes and migrate into indoor spaces. Despite field data confirming the presence of this exposure pathway, there is lack of context-based numerical models that provide guidance to characterize and predict VOCs concentration in sewer gas at vapor intrusion sites. Particularly, this poses a challenge when assessing and mitigating risks associated with these exposure pathways. Therefore, a numerical model has been developed to simulate the concentration of VOCs in sewer gas in different stages throughout the sewer lines. The developed model considers various input parameters, including temperature, sewer liquid depth, groundwater depth, and sewer construction characteristics to incorporate local and operational conditions. The model's output is verified using field data from a sewer system constructed near a Superfund site. Moreover, a sensitivity analysis was conducted to evaluate the model's response to variation of the external input parameters. To the best of our knowledge, this study is the first attempt to model VOCs concentration in sewer gas, particularly to address vapor intrusion. The developed model can be used as a numerical tool to support the development of sewer assessment guidelines, risk assessment studies, and mitigation strategies"
Keywords:
Notes:"PubMed-not-MEDLINERoghani, Mahammadyousef Li, Ying Rezaei, Nader Robinson, Ariel Shirazi, Elham Pennell, Kelly G eng P30 ES026529/ES/NIEHS NIH HHS/ P42 ES007380/ES/NIEHS NIH HHS/ 2022/01/13 Ground Water Monit Remediat. 2021 Spring; 41(2):112-121. doi: 10.1111/gwmr.12449. Epub 2021 Apr 12"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024