« Previous AbstractData on comparison between FLEC and CLIMPAQ methods used for fast sorption measurements of VOCs on building materials    Next AbstractImpact of material emissions and sorption of volatile organic compounds on indoor air quality in a low energy building: Field measurements and modeling »

Data Brief


Title:Fast sorption measurements of volatile organic compounds on building materials: Part 1 - Methodology developed for field applications
Author(s):Rizk M; Verriele M; Dusanter S; Schoemaecker C; Le Calve S; Locoge N;
Address:"Mines Douai, SAGE, F-59508 Douai, France; Universite de Lille, F-59000 Lille, France; Universite de Strasbourg/CNRS, Institut de Chimie et Procedes pour l'Energie, l'Environnement et la Sante (ICPEES), UMR 7515, F-67087 Strasbourg, France. Mines Douai, SAGE, F-59508 Douai, France; Universite de Lille, F-59000 Lille, France. Universite de Lille 1, Laboratoire de Physico-chimie des Processus de Combustion et de l??Atmosphere, Villeneuve d??Ascq, France. Universite de Strasbourg/CNRS, Institut de Chimie et Procedes pour l'Energie, l'Environnement et la Sante (ICPEES), UMR 7515, F-67087 Strasbourg, France"
Journal Title:Data Brief
Year:2016
Volume:20160113
Issue:
Page Number:953 - 958
DOI: 10.1016/j.dib.2016.01.011
ISSN/ISBN:2352-3409 (Print) 2352-3409 (Electronic) 2352-3409 (Linking)
Abstract:"A Proton Transfer Reaction-Mass Spectrometer (PTR-MS) has been coupled to the outlet of a Field and Laboratory Emission Cell (FLEC), to measure volatile organic compounds (VOC) concentration during a sorption experiments (Rizk et al., this issue) [1]. The limits of detection of the PTR-MS for three VOCs are presented for different time resolution (2, 10 and 20 s). The mass transfer coefficient was calculated in the FLEC cavity for the different flow rates. The concentration profile obtained from a sorption experiment performed on a gypsum board and a vinyl flooring are also presented in comparison with the profile obtained for a Pyrex glass used as a material that do not present any sorption behavior (no sink). Finally, the correlation between the concentration of VOCs adsorbed on the surface of the gypsum board at equilibrium (Cse ) and the concentration of VOCs Ce measured in the gas phase at equilibrium is presented for benzene, C8 aromatics and toluene"
Keywords:
Notes:"PubMed-not-MEDLINERizk, M Verriele, M Dusanter, S Schoemaecker, C Le Calve, S Locoge, N eng Netherlands 2016/03/05 Data Brief. 2016 Jan 13; 6:953-8. doi: 10.1016/j.dib.2016.01.011. eCollection 2016 Mar"

 