« Previous AbstractCorrelation between Odor Concentration and Volatile Organic Compounds (VOC) Composition of Environmental Tobacco Smoke (ETS)    Next Abstract"An almost nontoxic tetrodotoxin analog, 5,6,11-trideoxytetrodotoxin, as an odorant for the grass puffer" »

Int J Environ Res Public Health


Title:Measurements of Volatile Organic Compounds in a Newly Built Daycare Center
Author(s):Noguchi M; Mizukoshi A; Yanagisawa Y; Yamasaki A;
Address:"Department of Materials and Life Science, Faculty of Science and Technology, Seikei University, 3-3-1 Kichijoji-kitamachi, Musashino, Tokyo 180-8633, Japan. noguchi@ejs.seikei.ac.jp. Department of Environmental Medicine and Behavioral Science, Kindai University, 377-2 Ohno-higashi, Osakasayama 589-8511, Japan. mizukoshi@med.kindai.ac.jp. Department of Environmental Systems, Institute of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563, Japan. yukio@kaiseigakuen.jp. Department of Materials and Life Science, Faculty of Science and Technology, Seikei University, 3-3-1 Kichijoji-kitamachi, Musashino, Tokyo 180-8633, Japan. akihiro@st.seikei.ac.jp"
Journal Title:Int J Environ Res Public Health
Year:2016
Volume:20160721
Issue:5
Page Number: -
DOI: 10.3390/ijerph13070736
ISSN/ISBN:1660-4601 (Electronic) 1661-7827 (Print) 1660-4601 (Linking)
Abstract:"We measured temporal changes in concentrations of total volatile organic compounds (TVOCs) and individual volatile organic compounds in a newly built daycare center. The temporal changes of the TVOC concentrations were monitored with a photo ionization detector (PID), and indoor air was sampled and analyzed by Gas Chromatography/Mass Spectrometry (GC/MS) and high performance liquid chromatography (HPLC) to determine the concentrations of the constituent VOCs. The measurements were performed just after completion of the building and again 3 months after completion. The TVOC concentration exceeded 1000 microg.m(-3) for all the sampling locations just after completion of building, and decreased almost one tenth after 3 months, to below the guideline values of the TVOC in Japan at 400 microg.m(-3). The concentrations of the target VOCs of which the indoor concentrations are regulated in Japan were below the guideline values for all the cases. The air-exchange rates were determined based on the temporal changes of the TVOC concentrations, and it was found that the countermeasure to increase the air exchange rate successfully decrease the TVOC concentration level in the rooms"
Keywords:"Air Pollutants/*analysis Air Pollution, Indoor/*analysis Child *Child Day Care Centers Environmental Monitoring/methods Gas Chromatography-Mass Spectrometry Humans Japan Volatile Organic Compounds/*analysis Tvoc VOCs air exchange rate guideline value indo;"
Notes:"MedlineNoguchi, Miyuki Mizukoshi, Atsushi Yanagisawa, Yukio Yamasaki, Akihiro eng Switzerland 2016/07/28 Int J Environ Res Public Health. 2016 Jul 21; 13(5):736. doi: 10.3390/ijerph13070736"

 