Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Emission factors and source profiles of volatile organic compounds from typical industrial sources in Guangzhou, China"    Next AbstractDefense responses of arbuscular mycorrhizal fungus-colonized poplar seedlings against gypsy moth larvae: a multiomics study »

Huan Jing Ke Xue


Title:[Level and characteristics of indoor air pollutants in a furniture mall in Beijing]
Author(s):Jiang CJ; Li SS; Zhang PY; Wang J;
Address:"State Key Joint Laboratory of Environmental Simulation and Pollution Control, Department of Environmental Science and Engineering, Tsinghua University, Beijing 100084, China. jiangcj05@126.com"
Journal Title:Huan Jing Ke Xue
Year:2010
Volume:31
Issue:12
Page Number:2860 - 2865
DOI:
ISSN/ISBN:0250-3301 (Print) 0250-3301 (Linking)
Abstract:"Concentrations of BTX (benzene, toluene and xylene), total volatile organic compounds (TVOC), formaldehyde and other carbonyl compounds were measured in different sections of a furniture mall in Beijing. The overall indoor concentrations (mean +/- standard deviation) of formaldehyde, benzene, toluene, xylene, and TVOC were (0.37 +/- 0.08), (0.04 +/- 0.03), (0.19 +/- 0.16), (0.47 +/- 0.57), and (2.76 +/- 2.18) mg/m3, respectively. Indoor concentrations of formaldehyde, xylene and TVOC were 22, 46 and 34 times higher than the corresponding outdoor concentrations respectively. Concentrations of formaldehyde, xylene and TVOC were much higher than the standard limits regulated in the national 'indoor air quality standard' (GB/T 18883-2002), and the highest concentrations of formaldehyde and TVOC exceeded the standard limit 5.1 and 14.8 times respectively. Total concentration of carbonyl compounds was (689.3 +/- 94.8) microg/m3, which was 5 times higher than that outdoors. Of the carbonyls, formaldehyde and acetaldehyde were found to be the most abundant, together accounting for over 75% of the total carbonyl concentrations. Acetone, C4 carbonyls (methacrolein, methyl ethyl ketone, butanal), and hexanal also occurred at relatively high concentrations. In conclusion, indoor air pollution is serious in the furniture mall"
Keywords:"Acetaldehyde/analysis Air Pollution, Indoor/*analysis China Formaldehyde/*analysis *Interior Design and Furnishings Volatile Organic Compounds/*analysis;"
Notes:"MedlineJiang, Chuan-Jia Li, Shen-Shen Zhang, Peng-Yi Wang, Juan chi English Abstract Research Support, Non-U.S. Gov't China 2011/03/03 Huan Jing Ke Xue. 2010 Dec; 31(12):2860-5"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024