Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMonitoring of cocoa volatiles produced during roasting by selected ion flow tube-mass spectrometry (SIFT-MS)    Next AbstractEvaluation and characterization of volatile air toxics indoors in a heavy polluted city of northwestern China in wintertime »

Int J Anal Chem


Title:Development of a Portable Single Photon Ionization-Photoelectron Ionization Time-of-Flight Mass Spectrometer
Author(s):Huang Y; Li J; Tang B; Zhu L; Hou K; Li H;
Address:"Electric Power Research Institute, Guangxi Power Grid Corporation, Nanning 530023, China. Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China"
Journal Title:Int J Anal Chem
Year:2015
Volume:20151026
Issue:
Page Number:581696 -
DOI: 10.1155/2015/581696
ISSN/ISBN:1687-8760 (Print) 1687-8779 (Electronic) 1687-8760 (Linking)
Abstract:"A vacuum ultraviolet lamp based single photon ionization- (SPI-) photoelectron ionization (PEI) portable reflecting time-of-flight mass spectrometer (TOFMS) was designed for online monitoring gas samples. It has a dual mode ionization source: SPI for analyte with ionization energy (IE) below 10.6 eV and PEI for IE higher than 10.6 eV. Two kinds of sampling inlets, a capillary inlet and a membrane inlet, are utilized for high concentration and trace volatile organic compounds, respectively. A mass resolution of 1100 at m/z 64 has been obtained with a total size of 40 x 31 x 29 cm, the weight is 27 kg, and the power consumption is only 70 W. A mixture of benzene, toluene, and xylene (BTX), SO2, and discharging products of SF6 were used to test its performance, and the result showed that the limit of quantitation for BTX is as low as 5 ppbv (S/N = 10 : 1) with linear dynamic ranges greater than four orders of magnitude. The portable TOFMS was also evaluated by analyzing volatile organic compounds from wine and decomposition products of SF6 inside of a gas-insulated switchgear"
Keywords:
Notes:"PubMed-not-MEDLINEHuang, Yunguang Li, Jinxu Tang, Bin Zhu, Liping Hou, Keyong Li, Haiyang eng Egypt 2015/11/21 Int J Anal Chem. 2015; 2015:581696. doi: 10.1155/2015/581696. Epub 2015 Oct 26"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024