Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Biomonitoring-based exposure assessment of benzene, toluene, ethylbenzene and xylene among workers at petroleum distribution facilities"    Next AbstractA new SLA-aware method for discovering the cloud services using an improved nature-inspired optimization algorithm »

Am Ind Hyg Assoc J


Title:Occupational exposure and indoor air quality monitoring in a composting facility
Author(s):Heida H; Bartman F; van der Zee SC;
Address:"OMEGAM, Environmental Research Institute, City of Amsterdam, The Netherlands"
Journal Title:Am Ind Hyg Assoc J
Year:1995
Volume:56
Issue:1
Page Number:39 - 43
DOI: 10.1080/15428119591017295
ISSN/ISBN:0002-8894 (Print) 0002-8894 (Linking)
Abstract:"The objective of this study was to investigate indoor air quality in a completely covered enclosure used for the aerobic composting of organic wastes originating from vegetable, fruit, and garden refuse. Samples of gases and vapors were taken in the ventilation exhaust ducts. Volatile organic compounds (VOCs) were collected on Tenax absorbent; after thermal desorption they were analyzed by gas chromatography/mass spectrometry. Hydrogen sulfide was determined using Drager test tubes. Microbial samplings were conducted on four sites inside the hall. Microbes were collected using a modified Anderson high-volume sampler, consisting of two impactor stages. Results indicate that the concentrations of VOCs were rather low; only the limonene level was elevated, but it was still well below the current Dutch provisional threshold limit value. Hydrogen sulfide levels found were also far less than the Dutch threshold limit value. Both total bacteria and gram-negative bacterial counts exceeded the provisional Dutch guideline of 10,000 cfu/m3 for indoor air in the work environment. Furthermore, the number of fungi, for the larger part consisting of the genera Aspergillus and Penicillium, which are known to cause respiratory tract disorders, approached the hazardous exposure level"
Keywords:"Air Pollutants, Occupational/analysis *Air Pollution, Indoor Ecology *Environment, Controlled *Environmental Monitoring Humans Maximum Allowable Concentration *Occupational Exposure;"
Notes:"MedlineHeida, H Bartman, F van der Zee, S C eng 1995/01/01 Am Ind Hyg Assoc J. 1995 Jan; 56(1):39-43. doi: 10.1080/15428119591017295"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024