Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractRelationship between VOC and NOx emissions and chemical production of tropospheric ozone in the Aburra Valley (Colombia)    Next Abstract"RAD9 and RAD24 define two additive, interacting branches of the DNA damage checkpoint pathway in budding yeast normally required for Rad53 modification and activation" »

Air Qual Atmos Health


Title:Testing the single-pass VOC removal efficiency of an active green wall using methyl ethyl ketone (MEK)
Author(s):Torpy F; Clements N; Pollinger M; Dengel A; Mulvihill I; He C; Irga P;
Address:"1Plants and Environmental Quality Research Group, School of Life Sciences, Faculty of Science, University of Technology Sydney, Sydney, Australia. ISNI: 0000 0004 1936 7611. GRID: grid.117476.2 Well Living Lab, Rochester, MN USA. Delos Labs, Delos, New York, NY USA. 4General Internal Medicine, Mayo Clinic, Rochester, MN USA. ISNI: 0000 0004 0459 167X. GRID: grid.66875.3a Delos, New York, NY USA. 6Building Research Establishment, Watford, UK. ISNI: 0000 0001 0816 3312. GRID: grid.30073.37"
Journal Title:Air Qual Atmos Health
Year:2018
Volume:20171027
Issue:2
Page Number:163 - 170
DOI: 10.1007/s11869-017-0518-4
ISSN/ISBN:1873-9318 (Print) 1873-9326 (Electronic) 1873-9318 (Linking)
Abstract:"In recent years, research into the efficacy of indoor air biofiltration mechanisms, notably living green walls, has become more prevalent. Whilst green walls are often utilised within the built environment for their biophilic effects, there is little evidence demonstrating the efficacy of active green wall biofiltration for the removal of volatile organic compounds (VOCs) at concentrations found within an interior environment. The current work describes a novel approach to quantifying the VOC removal effectiveness by an active living green wall, which uses a mechanical system to force air through the substrate and plant foliage. After developing a single-pass efficiency protocol to understand the immediate effects of the system, the active green wall was installed into a 30-m(3) chamber representative of a single room and presented with the contaminant 2-butanone (methyl ethyl ketone; MEK), a VOC commonly found in interior environments through its use in textile and plastic manufacture. Chamber inlet levels of MEK remained steady at 33.91 +/- 0.541 ppbv. Utilising a forced-air system to draw the contaminated air through a green wall based on a soil-less growing medium containing activated carbon, the combined effects of substrate media and botanical component within the biofiltration system showed statistically significant VOC reduction, averaging 57% single-pass removal efficiency over multiple test procedures. These results indicate a high level of VOC removal efficiency for the active green wall biofilter tested and provide evidence that active biofiltration may aid in reducing exposure to VOCs in the indoor environment"
Keywords:Air pollution Biofiltration Cadr Indoor air Indoor plants Phytoremediation;
Notes:"PubMed-not-MEDLINETorpy, Fraser Clements, Nicholas Pollinger, Max Dengel, Andy Mulvihill, Isaac He, Chuan Irga, Peter eng Netherlands 2018/03/24 Air Qual Atmos Health. 2018; 11(2):163-170. doi: 10.1007/s11869-017-0518-4. Epub 2017 Oct 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024