Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVolatile compounds for biotechnological applications produced during competitive interactions between yeasts and fungi    Next Abstract"Volatile Organic Compounds from Cassava Plants Confer Resistance to the Whitefly Aleurothrixus aepim (Goeldi, 1886)" »

Talanta


Title:The screening of organic matter in mineral and tap water by UHPLC-HRMS
Author(s):Ribeiro MAS; Murgu M; Silva VM; Sawaya A; Ribeiro LF; Justi A; Meurer EC;
Address:"Federal University of Parana (UFPR), Jandaia do Sul, PR, Brazil. Electronic address: marcosquimicauem@hotmail.com. Waters Technologies, 13083-970 Sao Paulo, SP, Brazil. Federal University of Parana (UFPR), Jandaia do Sul, PR, Brazil. University of Campinas (UNICAMP), Campinas, SP, Brazil"
Journal Title:Talanta
Year:2017
Volume:20170624
Issue:
Page Number:581 - 586
DOI: 10.1016/j.talanta.2017.06.055
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"It is highly desirable to screen for a large variety of organic compounds in water. Ultra-high performance liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS) can analyse semi-polar to polar organic compounds in tap and mineral water. The use of UHPLC-HRMS is well consolidated for lipidomic, metabolomic and proteomic studies; based on the detection of a very large number of compounds of a variety of organic functions. Water analysis is usually performed by gas chromatography -mass spectrometry (GC-MS) techniques that are efficient for volatile organic compounds. Therefore the use of UHPLC-HRMS as a screening method based on an untargeted omic approach for the analysis of organic compounds with polar functional groups is welcome. This UHPLC-HRMS method was developed and tested with tap water and mineral water. We analysed six different brands of mineral water from France, Spain, Norway and Brazil and tap water from Jandaia do Sul, PR, Brazil to test the approach and demonstrate how UHPLC-HRMS may be used as a screening method for water quality. Forty-seven different ions were observed in tap and mineral water and their intensities were submitted to principal component analysis (PCA) evaluation. Fifteen ions were identified comparing the mass spectrometric results to metabolomic and lipidomic libraries"
Keywords:Organic compounds Pca Water analysis;
Notes:"PubMed-not-MEDLINERibeiro, Marcos A S Murgu, Michael Silva, Valquiria de Moraes Sawaya, Alexandra C H F Ribeiro, Leomara Floriano Justi, Andre Meurer, Eduardo C eng Netherlands 2017/07/26 Talanta. 2017 Nov 1; 174:581-586. doi: 10.1016/j.talanta.2017.06.055. Epub 2017 Jun 24"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024