Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Heat and PAHs Emissions in Indoor Kitchen Air and Its Impact on Kidney Dysfunctions among Kitchen Workers in Lucknow, North India"    Next AbstractHelicoverpa-inducible Thioredoxin h from Cicer arietinum: structural modeling and potential targets »

Environ Health


Title:"Indoor air pollution and its association with poor lung function, microalbuminuria and variations in blood pressure among kitchen workers in India: a cross-sectional study"
Author(s):Singh A; Kesavachandran CN; Kamal R; Bihari V; Ansari A; Azeez PA; Saxena PN; Ks AK; Khan AH;
Address:"Epidemiology Laboratory, Systems Toxicology and Health Risk Assessment Group, CSIR-Indian Institute of Toxicology Research (CSIR-IITR) , Vishvigyan Bhavan, 31, Mahatma Gandhi Marg, Lucknow, 226001, Uttar Pradesh, India. Department of Biochemistry, Babu Banarasi Das University, BBD City, Faizabad Road, Lucknow, 226028, Uttar Pradesh, India. Epidemiology Laboratory, Systems Toxicology and Health Risk Assessment Group, CSIR-Indian Institute of Toxicology Research (CSIR-IITR) , Vishvigyan Bhavan, 31, Mahatma Gandhi Marg, Lucknow, 226001, Uttar Pradesh, India. ckesavachandran@gmail.com. Salim Ali Centre for Ornithology and Natural History, Ministry of Environment, Forest and Climate Change, Government of India, Anaikatty, Coimbatore, 641108, Tamil Nadu, India. Advance Imaging Facility, CSIR-Indian Institute of Toxicology Research (CSIR-IITR), Vishvigyan Bhavan, 31, Mahatma Gandhi Marg, Lucknow, 226001, Uttar Pradesh, India. Medicinal and Process Chemistry Division, CSIR-Central Drug Research Institute (CSIR-CDRI), Sector-10, Jankipuram Extension, Sitapur Road, Lucknow, 226031, Uttar Pradesh, India. Environmental Monitoring Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research (CSIR-IITR), Vishvigyan Bhavan, 31, Mahatma Gandhi Marg, Lucknow, 226001, Uttar Pradesh, India"
Journal Title:Environ Health
Year:2017
Volume:20170404
Issue:1
Page Number:33 -
DOI: 10.1186/s12940-017-0243-3
ISSN/ISBN:1476-069X (Electronic) 1476-069X (Linking)
Abstract:"BACKGROUND: The present study is an attempt to explore the association between kitchen indoor air pollutants and physiological profiles in kitchen workers with microalbuminuria (MAU) in north India (Lucknow) and south India (Coimbatore). METHODS: The subjects comprised 145 control subjects, 233 kitchen workers from north India and 186 kitchen workers from south India. Information related to the personal and occupational history and health of the subjects at both locations were collected using a custom-made questionnaire. Worker lung function was measured using a spirometer. Blood pressure was monitored using a sphygmomanometer. Urinary MAU was measured using a urine analyzer. Indoor air monitoring in kitchens for particulate matter (PM), total volatile organic compounds (TVOC), carbon dioxide (CO(2)) and carbon monoxide (CO) was conducted using indoor air quality monitors. The size and shape of PM in indoor air was assessed using a scanning electron microscope (SEM). Fourier transform infrared (FTIR) spectroscopy was used to detect organic or inorganic compounds in the air samples. RESULTS: Particulate matter concentrations (PM(2.5) and PM(1)) were significantly higher in both north and south Indian kitchens than in non-kitchen areas. The concentrations of TVOC, CO and CO(2) were higher in the kitchens of north and south India than in the control locations (non-kitchen areas). Coarse, fine and ultrafine particles and several elements were also detected in kitchens in both locations by SEM and elemental analysis. The FTIR spectra of kitchen indoor air at both locations show the presence of organic chemicals. Significant declines in systolic blood pressure and lung function were observed in the kitchen workers with MAU at both locations compared to those of the control subjects. A higher prevalence of obstruction cases with MAU was observed among the workers in the southern region than in the controls (p < 0.01). CONCLUSIONS: Kitchen workers in south India have lower lung capacities and a greater risk of obstructive and restrictive abnormalities than their north Indian counterparts. The study showed that occupational exposure to multiple kitchen indoor air pollutants (ultrafine particles, PM(2.5), PM(1), TVOC, CO, CO(2)) and FTIR-derived compounds can be associated with a decline in lung function (restrictive and obstructive patterns) in kitchen workers with microalbuminuria. Further studies in different geographical locations in India among kitchen workers on a wider scale are required to validate the present findings"
Keywords:"Adolescent Adult Air Pollutants, Occupational/*analysis Air Pollution, Indoor/analysis Albuminuria/*epidemiology/physiopathology/urine Blood Pressure Carbon Dioxide/analysis Carbon Monoxide/analysis *Cooking Environmental Monitoring Humans India Lung/phys;"
Notes:"MedlineSingh, Amarnath Kesavachandran, Chandrasekharan Nair Kamal, Ritul Bihari, Vipin Ansari, Afzal Azeez, Parappurath Abdul Saxena, Prem Narain Ks, Anil Kumar Khan, Altaf Hussain eng Research Support, Non-U.S. Gov't England 2017/04/06 Environ Health. 2017 Apr 4; 16(1):33. doi: 10.1186/s12940-017-0243-3"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024