Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Cytokinins act synergistically with heat acclimation to enhance rice thermotolerance affecting hormonal dynamics, gene expression and volatile emission"    Next Abstract"The compartment structures of the antennal lobe in the ant, Aphaenogaster smythiesi japonica" »

Sensors (Basel)


Title:Diagnosis by Volatile Organic Compounds in Exhaled Breath from Lung Cancer Patients Using Support Vector Machine Algorithm
Author(s):Sakumura Y; Koyama Y; Tokutake H; Hida T; Sato K; Itoh T; Akamatsu T; Shin W;
Address:"Department of Information Science and Technology, Aichi Prefectural University, Nagakute 480-1198, Japan. sakumura@ist.aichi-pu.ac.jp. Department of Information Science and Technology, Aichi Prefectural University, Nagakute 480-1198, Japan. sonic.h.0715@gmail.com. Department of Information Science and Technology, Aichi Prefectural University, Nagakute 480-1198, Japan. tokusanpc@gmail.com. Department of Thoracic Oncology, Aichi Cancer Center, 1-1 Kanokoden, Chikusa-ku, Nagoya 464-8681, Japan. 107974@aichi-cc.jp. Department of Mechanical Engineering, Aichi Institute of Technology, Toyota, 470-0392, Japan. sato@aitech.ac.jp. Department of Materials and Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Shimo-Shidami, Moriyama-ku, Nagoya 463-8560, Japan. itoh-toshio@aist.go.jp. Department of Materials and Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Shimo-Shidami, Moriyama-ku, Nagoya 463-8560, Japan. t-akamatsu@aist.go.jp. Department of Materials and Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Shimo-Shidami, Moriyama-ku, Nagoya 463-8560, Japan. w.shin@aist.go.jp"
Journal Title:Sensors (Basel)
Year:2017
Volume:20170204
Issue:2
Page Number: -
DOI: 10.3390/s17020287
ISSN/ISBN:1424-8220 (Electronic) 1424-8220 (Linking)
Abstract:"Monitoring exhaled breath is a very attractive, noninvasive screening technique for early diagnosis of diseases, especially lung cancer. However, the technique provides insufficient accuracy because the exhaled air has many crucial volatile organic compounds (VOCs) at very low concentrations (ppb level). We analyzed the breath exhaled by lung cancer patients and healthy subjects (controls) using gas chromatography/mass spectrometry (GC/MS), and performed a subsequent statistical analysis to diagnose lung cancer based on the combination of multiple lung cancer-related VOCs. We detected 68 VOCs as marker species using GC/MS analysis. We reduced the number of VOCs and used support vector machine (SVM) algorithm to classify the samples. We observed that a combination of five VOCs (CHN, methanol, CH(3)CN, isoprene, 1-propanol) is sufficient for 89.0% screening accuracy, and hence, it can be used for the design and development of a desktop GC-sensor analysis system for lung cancer"
Keywords:Algorithms Breath Tests Exhalation Gas Chromatography-Mass Spectrometry Humans *Lung Neoplasms Support Vector Machine Volatile Organic Compounds exhaled air gas chromatography-mass spectrometry analysis lung cancer screening support vector machine (SVM) v;
Notes:"MedlineSakumura, Yuichi Koyama, Yutaro Tokutake, Hiroaki Hida, Toyoaki Sato, Kazuo Itoh, Toshio Akamatsu, Takafumi Shin, Woosuck eng Switzerland 2017/02/07 Sensors (Basel). 2017 Feb 4; 17(2):287. doi: 10.3390/s17020287"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024