Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCalibration of an in situ membrane inlet mass spectrometer for measurements of dissolved gases and volatile organics in seawater    Next Abstract"Aggressiveness in the cockroach Periplaneta americana (Orthoptera, Blattidae)" »

J Am Soc Mass Spectrom


Title:A field-portable membrane introduction mass spectrometer for real-time quantitation and spatial mapping of atmospheric and aqueous contaminants
Author(s):Bell RJ; Davey NG; Martinsen M; Collin-Hansen C; Krogh ET; Gill CG;
Address:"Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, Nanaimo, BC, Canada"
Journal Title:J Am Soc Mass Spectrom
Year:2015
Volume:20141205
Issue:2
Page Number:212 - 223
DOI: 10.1007/s13361-014-1028-3
ISSN/ISBN:1879-1123 (Electronic) 1044-0305 (Linking)
Abstract:"Environmental concentrations of volatile and semivolatile organic compounds (VOC/SVOCs) can vary dramatically in time and space under the influence of environmental conditions. In an industrial setting, multiple point and diffuse sources can contribute to fugitive emissions. Assessments and monitoring programs using periodic grab sampling provide limited information, often with delay times of days or weeks. We report the development and use of a novel, portable membrane introduction mass spectrometry (MIMS) system capable of resolving and quantifying VOC and SVOCs with high spatial and temporal resolution, in the field, in real-time. An electron impact ionization cylindrical ion trap mass spectrometer modified with a capillary hollow fiber polydimethylsiloxane membrane interface was used for continuous air and water sampling. Tandem mass spectrometry and selected ion monitoring scans performed in series allowed for the quantitation of target analytes, and full scan mode was used to survey for unexpected analytes. Predeployment and in-field external calibrations were combined with a continuously infused internal standard to enable real-time quantitation and monitor instrument performance. The system was operated in a moving vehicle with internet-linked data processing and storage. Software development to integrate MIMS and relevant meta-data for visualization and geospatial presentation in Google Earth is presented. Continuous quantitation enables the capture of transient events that may be missed or under-represented by traditional grab sampling strategies. Real-time geospatial maps of chemical concentration enable adaptive sampling and in-field decision support. Sample datasets presented in this work were collected in Northern Alberta in 2010-2012"
Keywords:"Air Pollutants/*analysis Alberta Environmental Monitoring/instrumentation/*methods Equipment Design Internet Membranes, Artificial Software Tandem Mass Spectrometry/*instrumentation/methods Toluene/analysis Volatile Organic Compounds/analysis Water Pollut;"
Notes:"MedlineBell, Ryan J Davey, Nicholas G Martinsen, Morten Collin-Hansen, Christian Krogh, Erik T Gill, Christopher G eng Research Support, Non-U.S. Gov't 2014/12/06 J Am Soc Mass Spectrom. 2015 Feb; 26(2):212-23. doi: 10.1007/s13361-014-1028-3. Epub 2014 Dec 5"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024