Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractA healthy home environment?    Next AbstractEffects of Corsi-Rosenthal boxes on indoor air contaminants: non-targeted analysis using high resolution mass spectrometry »

J Chromatogr A


Title:Improved liquid chromatographic method with pulsed electrochemical detection for the analysis of kanamycin
Author(s):Manyanga V; Dhulipalla RL; Hoogmartens J; Adams E;
Address:"Laboratorium voor Farmaceutische Analyse, Faculteit Farmaceutische Wetenschappen, Katholieke Universiteit Leuven, O&N2 PB 923, Herestraat 49, B-3000, Leuven, Belgium"
Journal Title:J Chromatogr A
Year:2010
Volume:20100402
Issue:24
Page Number:3748 - 3753
DOI: 10.1016/j.chroma.2010.03.053
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"This work describes the separation of the main component kanamycin A from its related substances using an improved liquid chromatographic method with pulsed electrochemical detection (LC-PED). Two methods, one using volatile ion pairing agents and the other using non-volatile ones were developed. Using volatile additives, the total run time was rather long with no possibility of developing gradient elution. The non-volatile method was found to be more performant and hence was selected for further quantitative work. This method employed gradient elution in order to reduce the analysis time and to improve the sensitivity of the late eluting peaks. Mobile phase A consisted of sodium sulphate (5.0g/l), sodium octanesulphonate (0.5g/l) and 0.2M phosphate buffer pH 3.0 (50.0ml/l). Mobile phase B was the same as A except for the amount of sodium sulphate which was increased to 15g/l. Using a Platinum EPS column (150mmx4.6mm ID, 3microm) kept at 45 degrees C, 22 components could be separated within 45min indicating that this method is much more selective than other already published ones. Robustness of the method was examined by means of an experimental design. The limit of detection and limit of quantitation were found to be 1.7 and 5ng, respectively. The method was found to be linear in the range LOQ-600ng injected with a coefficient of determination equal to 0.999"
Keywords:"Chromatography, Liquid/*methods Electrochemical Techniques/*methods Kanamycin/*analysis/chemistry Linear Models Models, Statistical Reproducibility of Results Sensitivity and Specificity Temperature Trifluoroacetic Acid/chemistry Volatile Organic Compound;"
Notes:"MedlineManyanga, Vicky Dhulipalla, Rajya Lakshmi Hoogmartens, Jos Adams, Erwin eng Netherlands 2010/05/07 J Chromatogr A. 2010 Jun 11; 1217(24):3748-53. doi: 10.1016/j.chroma.2010.03.053. Epub 2010 Apr 2"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-09-2024